Evidence map›Paper›PMID 28034638›Full record

ArticleMagnetic resonance imaging2017

Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory.

M Usman, B Ruijsink, M S Nazir, G Cruz, C Prieto

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Comprehensive review of artifacts in cardiac MRI and their mitigation.The international journal of cardiovascular imaging · 2024
    Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

M UsmanKing's College London, Division of Imaging Sciences and Biomedical Engineering, London, United Kingdom; Department of Computer Science, University College London, London, UK. Electronic address: muhammad.usman@kcl.ac.uk.
B RuijsinkKing's College London, Division of Imaging Sciences and Biomedical Engineering, London, United Kingdom.
M S NazirKing's College London, Division of Imaging Sciences and Biomedical Engineering, London, United Kingdom.
G CruzKing's College London, Division of Imaging Sciences and Biomedical Engineering, London, United Kingdom.
C PrietoKing's College London, Division of Imaging Sciences and Biomedical Engineering, London, United Kingdom; Pontificia Universidad Católica de Chile, Escuela de Ingeniería, Santiago, Chile.

Funding

Medical Research Council MR/L009676/1MRF_ C0510
6 · The paper itself

Abstract

purposeTo present a method that uses a novel free-running self-gated acquisition to achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI. MATERIAL AND

methods3D cardiac CINE MRI using navigator gating results in long acquisition times. Recently, several frameworks based on self-gated non-Cartesian trajectories have been proposed to accelerate this acquisition. However, non-Cartesian reconstructions are computationally expensive due to gridding, particularly in 3D. In this work, we propose a novel highly efficient self-gated Cartesian approach for 3D cardiac CINE MRI. Acquisition is performed using CArtesian trajectory with Spiral PRofile ordering and Tiny golden angle step for eddy current reduction (so called here CASPR-Tiger). Data is acquired continuously under free breathing (retrospective ECG gating, no preparation pulses interruption) for 4-5min and 4D whole-heart volumes (3D+cardiac phases) with isotropic spatial resolution are reconstructed from all available data using a soft gating technique combined with temporal total variation (TV) constrained iterative SENSE reconstruction.

resultsFor data acquired on eight healthy subjects and three patients, the reconstructed images using the proposed method had good contrast and spatio-temporal variations, correctly recovering diastolic and systolic cardiac phases. Non-significant differences (P>0.05) were observed in cardiac functional measurements obtained with proposed 3D approach and gold standard 2D multi-slice breath-hold acquisition.

conclusionThe proposed approach enables isotropic 3D whole heart Cartesian cardiac CINE MRI in 4 to 5min free breathing acquisition.

Indexed as

Breath HoldingImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineRespirationAdultAgedFemaleHealthy VolunteersHeartHeart DiseasesHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMaleMiddle AgedRetrospective Studies3D cardiac CINEFree breathingGolden angle stepSelf-gating

Identifiers

PMID28034638
PMCPMC5375620

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.