ArticlePloS one2016
Combined Low-Frequency Ultrasound and Urokinase-Containing Microbubbles in Treatment of Femoral Artery Thrombosis in a Rabbit Model.
Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 16 citations in OpenAlex.
- Contrast enhanced sonothrombolysis using streptokinase loaded phase change nano-droplets for potential treatment of deep venous thrombosis.RSC advances · 2022Article
- A thrombolytic therapy using diagnostic ultrasound combined with RGDS-targeted microbubbles and urokinase in a rabbit model.Scientific reports · 2020Article
- Advances in Sonothrombolysis Techniques Using Piezoelectric Transducers.Sensors (Basel, Switzerland) · 2020Review
- Recent strategies on targeted delivery of thrombolytics.Asian journal of pharmaceutical sciences · 2019Review
- Drug-Loaded Microbubbles Combined with Ultrasound for Thrombolysis and Malignant Tumor Therapy.BioMed research international · 2019Review
- The Optimized Fabrication of a Novel Nanobubble for Tumor Imaging.Frontiers in pharmacology · 2019Article
- [Efficacy of combined ultrasound and microbubble treatment for thrombolysis for rescuing ischemic tissues in rats at different time after thrombosis].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2018Article
- In vivo evaluation of urokinase-loaded hollow nanogels for sonothrombolysis on suture embolization-induced acute ischemic stroke rat model.Bioactive materials · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper aims to study the thrombolytic effect of low-frequency ultrasound combined with targeted urokinase-containing microbubble contrast agents on treatment of thrombosis in rabbit femoral artery; and to determine the optimal combination of parameters for achieving thrombolysis in this model. A biotinylated-avidin method was used to prepare microbubble contrast agents carrying urokinase and Arg-Gly-Asp-Ser (RGDS) peptides. Following femoral artery thrombosis in New Zealand white rabbits, microbubble contrast agents were injected intravenously, and ultrasonic exposure was applied. A 3 × 2 × 2 factorial table was applied to categorize the experimental animals based on different levels of combination of ultrasonic frequencies (Factor A: 1.6 MHz, 2.2 MHz, 2.8 MHz), doses of urokinase (Factor B: 90,000 IU/Kg, 180,000 IU/Kg) and ultrasound exposure time (Factor C: 30 min, 60 min). A total of 72 experimental animals were randomly divided into 12 groups (n = 6/group). Doppler techniques were used to assess blood flow in the distal end of the thrombotic femoral artery during the 120 minutes thrombolysis experiment. The rate of recanalization following thrombolysis was calculated, and thrombolytic efficacy was evaluated and compared. The thrombolytic recanalization rate for all experimental subjects after thrombolytic therapy was 68.1%. The optimal parameters for thrombolysis were determined to be 1) an ultrasound frequency of 2.2 MHz and 2) a 90,000 IU/kg dose of urokinase. Ultrasound exposure time (30 min vs. 60 min) had no significant effect on the thrombolytic effects. The combination of local low-frequency ultrasound radiation, targeted microbubbles, and thrombolytic urokinase induced thrombolysis of femoral artery thrombosis in a rabbit model. The ultrasonic frequency of 2.2 MHz and urokinase dose of 90,000 IU/kg induced optimal thrombolytic effects, while the application of either 30 min or 60 min of ultrasound exposure had similar effects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.