Evidence map›Paper›PMID 28033276›Full record

Trial reportMedicine2016

A novel automatic regulatory device for continuous bladder irrigation based on wireless sensor in patients after transurethral resection of the prostate: A prospective investigation.

Aimin Ding, Huling Cao, Lihua Wang, Jiangang Chen, Jian Wang, Bosheng He

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.4field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. An open-source, non-invasive, novel assembly for automated real-time monitoring of continuous bladder irrigation.Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2023
    Article
  5. SafeSensors (Basel, Switzerland) · 2021
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Aimin DingDepartment of Urinary Surgery Department of Emergency Nursing Department Department of Equipment Department of Radiology, The Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, China.
Huling Cao
Lihua Wang
Jiangang Chen
Jian Wang
Bosheng He
Second Affiliated Hospital of Nantong University

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBenign prostatic hyperplasia is a common progressive disease in aging men, which leads to a significant impact on daily lives of patients. Continuous bladder irrigation (CBI) is a supplementary option for preventing the adverse events following transurethral resection of the prostate (TURP). Regulation of the flow rate based on the color of drainage bag is significant to prevent the clot formation and retention, which is controlled manually at present. To achieve a better control of flow rate and reduce inappropriate flow rate-related adverse effects, we designed an automatic flow rate controller for CBI applied with wireless sensor and evaluated its clinical efficacy.

methodsThe therapeutic efficacy was evaluated in patients receiving the novel automatic bladder irrigation post-TURP in the experimental group compared with controls receiving traditional bladder irrigation in the control group.

resultsA total of 146 patients were randomly divided into 2 groups-the experimental group (n = 76) and the control group (n = 70). The mean irrigation volume of the experimental group (24.2 ± 3.8 L) was significantly lower than that of the controls (54.6 ± 5.4 L) (P < 0.05). Patients treated with automatic irrigation device had significantly decreased incidence of clot retention (8/76) and cystospasm (12/76) compared to controls (21/70; 39/70, P < 0.05). There was no significant difference between the 2 groups with regard to irrigation time (28.6 ± 2.7 vs 29.5 ± 3.4 hours, P = 0.077).

conclusionThe study suggests that the automatic regulating device applied with wireless sensor for CBI is safe and effective for patients after TURP. However, studies with a large population of patients and a long-term follow-up should be conducted to validate our findings.

Indexed as

Urinary BladderAgedAged, 80 and overHumansMaleMiddle AgedProstatic HyperplasiaTherapeutic IrrigationTransurethral Resection of ProstateTreatment OutcomeWireless Technology

Identifiers

PMID28033276
PMCPMC5207572
OpenAlexW2561175693

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.