Evidence map›Paper›PMID 28033118›Full record

ArticlePhysics in medicine and biology2017

Multi-resolution statistical image reconstruction for mitigation of truncation effects: application to cone-beam CT of the head.

Hao Dang, J Webster Stayman, Alejandro Sisniega, Wojciech Zbijewski, Jennifer Xu, Xiaohui Wang, David H Foos, Nafi Aygun, Vassilis E Koliatsos, Jeffrey H Siewerdsen

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hao DangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, USA.
J Webster StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, USA.
Alejandro SisniegaDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, USA.
Wojciech ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, USA.
Jennifer XuDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, USA.
Xiaohui WangCarestream Health, Rochester, NY 14608, USA.
David H FoosCarestream Health, Rochester, NY 14608, USA.
Nafi AygunRussell H Morgan Department of Radiology, Johns Hopkins University, Baltimore MD 21205, USA.
Vassilis E KoliatsosDepartment of Neurology, Johns Hopkins University, Baltimore MD 21205, USA.
Jeffrey H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, USA.

Funding

Quantitative high resolution cone beam CT for assessment of bone and joint healthR01EB018896 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI ZBIJEWSKI, WOJCIECH BARTOSZ · 2014 to 2017
$2.0M
NIBIB NIH HHS R01 EB018896
6 · The paper itself

Abstract

A prototype cone-beam CT (CBCT) head scanner featuring model-based iterative reconstruction (MBIR) has been recently developed and demonstrated the potential for reliable detection of acute intracranial hemorrhage (ICH), which is vital to diagnosis of traumatic brain injury and hemorrhagic stroke. However, data truncation (e.g. due to the head holder) can result in artifacts that reduce image uniformity and challenge ICH detection. We propose a multi-resolution MBIR method with an extended reconstruction field of view (RFOV) to mitigate truncation effects in CBCT of the head. The image volume includes a fine voxel size in the (inner) nontruncated region and a coarse voxel size in the (outer) truncated region. This multi-resolution scheme allows extension of the RFOV to mitigate truncation effects while introducing minimal increase in computational complexity. The multi-resolution method was incorporated in a penalized weighted least-squares (PWLS) reconstruction framework previously developed for CBCT of the head. Experiments involving an anthropomorphic head phantom with truncation due to a carbon-fiber holder were shown to result in severe artifacts in conventional single-resolution PWLS, whereas extending the RFOV within the multi-resolution framework strongly reduced truncation artifacts. For the same extended RFOV, the multi-resolution approach reduced computation time compared to the single-resolution approach (viz. time reduced by 40.7%, 83.0%, and over 95% for an image volume of 600

Indexed as

Models, TheoreticalPhantoms, ImagingAlgorithmsArtifactsCone-Beam Computed TomographyHeadHumansImage Processing, Computer-Assisted

Identifiers

PMID28033118
PMCPMC5234681

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.