ArticleForensic science, medicine, and pathology2017
Validation of alternate light sources for detection of bruises in non-embalmed and embalmed cadavers.
Article in Forensic science, medicine, and pathology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 21 citations in OpenAlex.
- Bloody Evidence: The Validity of Glycophorin A in the Determination of Wound Vitality-A Systematic Review of the Literature.International journal of molecular sciences · 2025Pooled it
- Examining the use of alternative light sources in medico-legal assessments of blunt-force trauma: a systematic review.International journal of legal medicine · 2024Pooled it
- Detection of Inflicted Bruises by Alternate Light: Results of a Randomized Controlled Trial.Journal of forensic sciences · 2020Trial
- Forensic bruise documentation with alternate light sources: Preliminary observation on deceased individuals in a routine illuminated autopsy setting.Journal of forensic sciences · 2026Article
- Evaluation Framework for Bruise Detection: Systematic ALS/White-Light Training and Skin-Tone Balancing with Deep Learning.Sensors (Basel, Switzerland) · 2026Article
- Beyond the visible spectrum - applying 3D multispectral full-body imaging to the VirtoScan system.Forensic science, medicine, and pathology · 2021Article
- Evaluation of a model of bruising in pigmented skin for investigating the potential for alternate light source illumination to enhance the appearance of bruises by photography of visible and infrared light.Forensic science, medicine, and pathology · 2019Article
- A comparison of four different imaging modalities - Conventional, cross polarized, infra-red and ultra-violet in the assessment of childhood bruising.Journal of forensic and legal medicine · 2018Article
- Improving the Forensic Documentation of Injuries Through Alternate Light: A Researcher-Practitioner Partnership.Journal of forensic nursingArticle
- Alternate Light Source Findings of Common Topical Cosmetics and Three Removal Methods.Journal of forensic nursingArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Bruising is frequently documented in cases of violence for use as forensic evidence. However, bruises can be overlooked if they are not visible to the naked eye. Alternate light sources such as ultraviolet, narrow band, and infrared have been used in an attempt to reveal the presence of bruising that is not otherwise apparent. However, there is a significant gap in knowledge surrounding this technique as it has not been validated against histology to confirm that bruising is genuinely being enhanced. A recent study evaluated the ability of alternate light sources to enhance visibility of bruises using a pigskin model. However, histological confirmation of bruising in humans using these light sources has not yet been performed. In this study, embalmed and non-embalmed human cadavers were used. Bodies were surveyed with alternate light sources, and enhanced regions that were unapparent under white light were photographed with the alternate light sources and sampled for histological assessment. Immunohistochemical staining for the red blood cell surface protein glycophorin was used determine if the enhanced area was a bruise (defined by the presence of extravasated erythrocytes). Photographs of areas confirmed to be bruises were analyzed using the program Fiji to measure enhancement, which was defined as an increase in the measured transverse diameter. In the non-embalmed and the embalmed cadavers violet alternate light produced the greatest enhancement of histologically confirmed bruises, followed by blue (both p < 0.0001). Regions that were not confirmed as bruises also enhanced, indicating that light sources may not be specific. This suggests that the use of light sources to enhance the visibility of bruising should be undertaken with caution and further studies are required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.