Evidence map›Paper›PMID 28018711›Full record

ArticleBiomedical optics express2016

Cerebral capillary velocimetry based on temporal OCT speckle contrast.

Woo June Choi, Yuandong Li, Wan Qin, Ruikang K Wang

Abstract read
In one paragraph

Article in Biomedical optics express, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Measuring capillary flow dynamics using interlaced two-photon volumetric scanning.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2023
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Can OCT Angiography Be Made a Quantitative Blood Measurement Tool?Applied sciences (Basel, Switzerland) · 2017
    Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Woo June ChoiDepartment of Bioengineering, University of Washington, 3720 15th NE, Seattle, WA 98195, USA.
Yuandong LiDepartment of Bioengineering, University of Washington, 3720 15th NE, Seattle, WA 98195, USA.
Wan QinDepartment of Bioengineering, University of Washington, 3720 15th NE, Seattle, WA 98195, USA.
Ruikang K WangDepartment of Bioengineering, University of Washington, 3720 15th NE, Seattle, WA 98195, USA.

Funding

OPTICAL MICROANGIOGRAHY OF CEREBROVASCULAR PERFUSIONR01HL093140 · NHLBI · UNIVERSITY OF WASHINGTON · PI WANG, RUIKANG · 2008 to 2017
$4.2M
NON-INVASIVE REAL-TIME LABEL-FREE 3D IMAGING OF RETINAL MICROCIRCULATIONR01EY024158 · NEI · UNIVERSITY OF WASHINGTON · PI WANG, RUIKANG · 2014 to 2017
$1.7M
NEI NIH HHS R01 EY024158NHLBI NIH HHS R01 HL093140
6 · The paper itself

Abstract

We propose a new optical coherence tomography (OCT) based method to measure red blood cell (RBC) velocities of single capillaries in the cortex of rodent brain. This OCT capillary velocimetry exploits quantitative laser speckle contrast analysis to estimate speckle decorrelation rate from the measured temporal OCT speckle signals, which is related to microcirculatory flow velocity. We hypothesize that OCT signal due to sub-surface capillary flow can be treated as the speckle signal in the single scattering regime and thus its time scale of speckle fluctuations can be subjected to single scattering laser speckle contrast analysis to derive characteristic decorrelation time. To validate this hypothesis, OCT measurements are conducted on a single capillary flow phantom operating at preset velocities, in which M-mode B-frames are acquired using a high-speed OCT system. Analysis is then performed on the time-varying OCT signals extracted at the capillary flow, exhibiting a typical inverse relationship between the estimated decorrelation time and absolute RBC velocity, which is then used to deduce the capillary velocities. We apply the method to

Indexed as

(170.2655) Functional monitoring and imaging(170.4500) Optical coherence tomography(220.4000) Microstructure fabrication

Identifiers

PMID28018711
PMCPMC5175537

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked