ArticleDiabetes therapy : research, treatment and education of diabetes and related disorders2017
Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: a Multicenter, Open-Label Randomized Controlled Trial.
Article in Diabetes therapy : research, treatment and education of diabetes and related disorders, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 5 registered trials, which are not on this map. Cited by 308 papers, 14 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Randomised Controlled Study to Evaluate the Impact of Novel Glucose Sensing Technology on HbA1c in Type 2 Diabetes
Improving Glucose Control and Self-Management in Adults With Type 2 Diabetes From Health Disparate Groups Using Continuous Glucose Monitoring and Education Support
Effect of Monitoring With Freestyle Libre 2 Glucose Sensor on Treatment Satisfaction in Patients With Type 2 Diabetes Mellitus: Exploratory Study in Patients Starting Monitoring
CGM Boosted by Artificial Intelligence for Better Glycaemic Control in T2 Diabetes: a Real-life Multicentre Observational Study in Belgium.
Supporting Primary Care Adoption, Resources, and Knowledge for Continuous Glucose Monitoring
Who cites it
308 citing papers in PubMed, 14 syntheses or guidelines pooled it, 623 citations in OpenAlex.
- [Diabetes technology (Update 2026)].Wiener klinische Wochenschrift · 2026Guideline
- Efficacy of continuous glucose monitoring in comparison to self-blood glucose monitoring in patients with type 2 diabetes mellitus under insulin treatment: a systematic review and meta-analysis.BMC endocrine disorders · 2026Pooled it
- Impact of continuous glucose monitoring on patient-reported outcomes in adults with type 2 diabetes: a Systematic Review and meta-analysis.Frontiers in endocrinology · 2026Pooled it
- The therapeutic efficacy of continuous glucose monitoring in diabetes: an updated meta-analysis with meta-regression.Endocrine · 2025Pooled it
- The efficacy of using continuous glucose monitoring as a behaviour change tool in populations with and without diabetes: a systematic review and meta-analysis of randomised controlled trials.The international journal of behavioral nutrition and physical activity · 2024Pooled it
- 2023 Clinical Practice Guidelines for Diabetes Management in Korea: Full Version Recommendation of the Korean Diabetes Association.Diabetes & metabolism journal · 2024Guideline
- Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis.Diabetologia · 2024Pooled it
- 2023 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association.Diabetes & metabolism journal · 2023Guideline
- Effects of E-health-based interventions on glycemic control for patients with type 2 diabetes: a Bayesian network meta-analysis.Frontiers in endocrinology · 2023Pooled it
- American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2022Guideline
- Flash glucose monitoring in type 2 diabetes managed with basal insulin in the USA: a retrospective real-world chart review study and meta-analysis.BMJ open diabetes research & care · 2022Pooled it
- Efficacy of Flash Glucose Monitoring in Type 1 and Type 2 Diabetes: A Systematic Review and Meta-Analysis of Randomised Controlled Trials.Frontiers in clinical diabetes and healthcare · 2022Pooled it
- Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials.Acta diabetologica · 2021Pooled it
- A Systematic Review of Collective Evidences Investigating the Effect of Diabetes Monitoring Systems and Their Application in Health Care.Frontiers in endocrinology · 2021Pooled it
- Trial
- Lifestyle Intervention With Smartphone App and isCGM for People at High Risk of Type 2 Diabetes: Randomized Trial.The Journal of clinical endocrinology and metabolism · 2024Trial
- Trial
- Trial
- Trial
- Real-Time Flash Glucose Monitoring Had Better Effects on Daily Glycemic Control Compared With Retrospective Flash Glucose Monitoring in Patients With Type 2 Diabetes on Premix Insulin Therapy.Frontiers in endocrinology · 2022Trial
248 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
Authors and funding
6 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionGlycemic control in participants with insulin-treated diabetes remains challenging. We assessed safety and efficacy of new flash glucose-sensing technology to replace self-monitoring of blood glucose (SMBG).
methodsThis open-label randomized controlled study (ClinicalTrials.gov, NCT02082184) enrolled adults with type 2 diabetes on intensive insulin therapy from 26 European diabetes centers. Following 2 weeks of blinded sensor wear, 2:1 (intervention/control) randomization (centrally, using biased-coin minimization dependant on study center and insulin administration) was to control (SMBG) or intervention (glucose-sensing technology). Participants and investigators were not masked to group allocation. Primary outcome was difference in HbA1c at 6 months in the full analysis set. Prespecified secondary outcomes included time in hypoglycemia, effect of age, and patient satisfaction.
resultsParticipants (n = 224) were randomized (149 intervention, 75 controls). At 6 months, there was no difference in the change in HbA1c between intervention and controls: -3.1 ± 0.75 mmol/mol, [-0.29 ± 0.07% (mean ± SE)] and -3.4 ± 1.04 mmol/mol (-0.31 ± 0.09%) respectively; p = 0.8222. A difference was detected in participants aged <65 years [-5.7 ± 0.96 mmol/mol (-0.53 ± 0.09%) and -2.2 ± 1.31 mmol/mol (-0.20 ± 0.12%), respectively; p = 0.0301]. Time in hypoglycemia <3.9 mmol/L (70 mg/dL) reduced by 0.47 ± 0.13 h/day [mean ± SE (p = 0.0006)], and <3.1 mmol/L (55 mg/dL) reduced by 0.22 ± 0.07 h/day (p = 0.0014) for intervention participants compared with controls; reductions of 43% and 53%, respectively. SMBG frequency, similar at baseline, decreased in intervention participants from 3.8 ± 1.4 tests/day (mean ± SD) to 0.3 ± 0.7, remaining unchanged in controls. Treatment satisfaction was higher in intervention compared with controls (DTSQ 13.1 ± 0.50 (mean ± SE) and 9.0 ± 0.72, respectively; p < 0.0001). No serious adverse events or severe hypoglycemic events were reported related to sensor data use. Forty-two serious events [16 (10.7%) intervention participants, 12 (16.0%) controls] were not device-related. Six intervention participants reported nine adverse events for sensor-wear reactions (two severe, six moderate, one mild).
conclusionFlash glucose-sensing technology use in type 2 diabetes with intensive insulin therapy results in no difference in HbA1c change and reduced hypoglycemia, thus offering a safe, effective replacement for SMBG.
trial registrationClinicalTrials.gov identifier: NCT02082184.
fundingAbbott Diabetes Care.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.