Evidence map›Paper›PMID 27989921›Full record

ArticleActa biomaterialia2017

A model system for developing a tissue engineered meniscal enthesis.

Mary Clare McCorry, Melissa M Mansfield, Xiaozhou Sha, Daniel J Coppola, Jonathan W Lee, Lawrence J Bonassar

Abstract read
In one paragraph

Article in Acta biomaterialia, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mary Clare McCorryMeinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States. Electronic address: mcm338@cornell.edu.
Melissa M MansfieldMeinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States. Electronic address: mmm449@cornell.edu.
Xiaozhou ShaMeinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States. Electronic address: xs245@cornell.edu.
Daniel J CoppolaMeinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States. Electronic address: djc437@cornell.edu.
Jonathan W LeeMeinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States. Electronic address: jwl287@cornell.edu.
Lawrence J BonassarMeinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States; Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States. Electronic address: lb244@cornell.edu.

Funding

Clinical and Translational Science CenterTL1TR000459 · NCATS · WEILL MEDICAL COLL OF CORNELL UNIV · PI IMPERATO-MCGINLEY, JULIANNE L · 2012 to 2016
$451k
Howard Hughes Medical InstituteNCATS NIH HHS TL1 TR000459
6 · The paper itself

Abstract

The meniscus acts as a stabilizer, lubricator, and load distributer in the knee joint. The mechanical stability of the meniscus depends on its connection to the underlying bone by a fibrocartilage to bone transition zone called the meniscal enthesis. Tissue engineered menisci hold great promise as a treatment alternative however lack a means of integrated fixation to the underlying bone needed in order for a tissue engineered meniscal replacement to be successful. Tissue engineering the meniscal enthesis is a difficult task given the complex gradients of cell type, mineral, and extracellular matrix molecules. Therefore, there is a need for a simplified and high throughput enthesis model to test experimental parameters. The goal of this study was to develop a simplified enthesis model to test collagen integration with decellularized bone. We found that injection molding collagen into tubing loaded with decellularized bone plugs resulted in a scaffold with three regions: bone, bone-collagen, and collagen. Furthermore, collagen formation was directed in the axial direction by using mechanical fixation at the bony ends. The results of this study showed that this technique can be used to mimic the native enthesis morphology and serves as ideal test platform to generate a model tissue engineered enthesis. STATEMENT OF SIGNIFICANCE: The meniscal enthesis is a complex structure that is essential to mechanical stability of the meniscus and the knee joint. Several studies document the development of anatomically shaped tissue engineered meniscus constructs, but none have focused on how to integrate such tissues with underlying bone. This study establishes a simplified construct to model the meniscal enthesis composed of a collagen gel seeded with meniscal fibrochondrocytes integrated with decellularized cancellous bone. Mechanical fixation at the bony ends induced tissue integration of fibers into the bony tissue, which is critical for mechanical performance and has yet to be shown in enthesis literature. Our test platform is amenable to targeted experiments investigating mineralization gradients, collagen fiber alignment, cell population phenotype, and media conditioning with experimental impact on enthesis studies for meniscus, tendon, and ligament.

Indexed as

AnimalsCattleCollagenMeniscusTissue EngineeringTissue ScaffoldsCollagenCollagen fibersCollagen gelEnthesisIntegrationMeniscus

Identifiers

PMID27989921
PMCPMC7326006

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.