ArticleEJNMMI physics2016
A gamma-distribution convolution model of
Article in EJNMMI physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Comparison of the gamma-Pareto convolution with conventional methods of characterising metformin pharmacokinetics in dogs.Journal of pharmacokinetics and pharmacodynamics · 2020Pooled it
- A series acceleration algorithm for the gamma-Pareto (type I) convolution and related functions of interest for pharmacokinetics.Journal of pharmacokinetics and pharmacodynamics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe convolution approach to thyroid time-activity curve (TAC) data fitting with a gamma distribution convolution (GDC) TAC model following bolus intravenous injection is presented and applied to
resultsThe nine clinical GDC models, obtained from least counting error of counting, exhibited corrected (for 6 parameters) fit errors ranging from 0.998% to 1.82%. The range of all thyroid mean residence times (MRTs) was 212 to 699 min, which from noise injected simulations of each case had an average coefficient of variation of 0.7% and a not statistically significant accuracy error of 0.5% (p = 0.5, 2-sample paired t test). The slowest MRT value (699 min) was from a single thyroid lobe with a tissue diagnosed parathyroid adenoma also seen on scanning as retained marker. The two total thyroid ROIs without substantial pathology had MRT values of 278 and 350 min overlapping a published
conclusionsThe GDC models had a small enough TAC noise-image misregistration (0.8%) that they have a plausible use as simulations of thyroid activity for querying performance of other models such as washout models, for altered ROI size, noise, administered dose, and image framing rates. Indeed, of the four washout-only models tested, no single model approached the apparent accuracy of the GDC model using only 90 min of data. Ninety minutes is a long gamma-camera acquisition time for a patient, but a short a time for most kinetic models. Consequently, the results should be regarded as preliminary.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.