Evidence map›Paper›PMID 27983574›Full record

ArticleJournal of functional biomaterials2016

Use of Micropatterned Thin Film Nitinol in Carotid Stents to Augment Embolic Protection.

Mahdis Shayan, Brian T Jankowitz, Puneeth Shridhar, Youngjae Chun

Open access · goldAbstract read
In one paragraph

Article in Journal of functional biomaterials, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Mahdis ShayanDepartment of Industrial Engineering, University of Pittsburgh, Pittsburgh, PA 15213, USA. mas461@pitt.edu.
Brian T JankowitzDepartment of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA 15213, USA. btj1@pitt.edu.
Puneeth ShridharDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA. pus8@pitt.edu.
Youngjae ChunDepartment of Industrial Engineering, University of Pittsburgh, Pittsburgh, PA 15213, USA. yjchun@pitt.edu.
University of Pittsburgh · USUniversity of Pittsburgh Medical Center · US

Funding

A Novel Thin Film Nitinol Covered Carotid Artery Embolic Protection StentR03NS083956 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CHUN, YOUNG JAE · 2014 to 2015
$147k
NINDS NIH HHS R03 NS083956
6 · The paper itself

Abstract

Stenting is an alternative to endarterectomy for the treatment of carotid artery stenosis. However, stenting is associated with a higher risk of procedural stroke secondary to distal thromboembolism. Hybrid stents with a micromesh layer have been proposed to address this complication. We developed a micropatterned thin film nitinol (M-TFN) covered stent designed to prevent thromboembolism during carotid intervention. This innovation may obviate the need or work synergistically with embolic protection devices. The proposed double layered stent is low-profile, thromboresistant, and covered with a M-TFN that can be fabricated with fenestrations of varying geometries and sizes. The M-TFN was created in multiple geometries, dimensions, and porosities by sputter deposition. The efficiency of various M-TFN to capture embolic particles was evaluated in different atherosclerotic carotid stenotic conditions through in vitro tests. The covered stent prevented emboli dislodgement in the range of 70%-96% during 30 min duration tests. In vitro vascular cell growth study results showed that endothelial cell elongation, alignment and growth behaviour silhouettes significantly enhance, specifically on the diamond-shape M-TFN, with the dimensions of 145 µm × 20 µm and a porosity of 32%. Future studies will require in vivo testing. Our results demonstrate that M-TFN has a promising potential for carotid artery stenting.

Indexed as

carotid arterymicro mesh stentmicropatterningthin film nitinol

Identifiers

PMID27983574
PMCPMC5197993
OpenAlexW2546855332

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.