ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2017
Use of self-expanding stents for better intracranial flow diverter wall apposition.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 25 citations in OpenAlex.
- The "pipe-anchor" technique: A method for intra-aneurysmal loop reduction using a partially unsheathed pipeline stent.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Efficacy and safety of a new mechanical balloon-based flow diverter in the treatment of intracranial aneurysms.Journal of neurointerventional surgery · 2026Observational
- Mechanical behavior of functionally zoned hybrid intracranial stent integrating laser-cut and braided architectures.Frontiers in bioengineering and biotechnology · 2026Article
- A Proposed Grading Scale Based on Radiographic Imaging for Wall Apposition to Estimate Neurologic Complications after Flow Diverter Treatment.AJNR. American journal of neuroradiology · 2025Article
- Intraluminal Flow Diverter Design Primer for Neurointerventionalists.AJNR. American journal of neuroradiology · 2024Review
- Flow Diverter Performance Comparison of Different Wire Materials for Effective Intracranial Aneurysm Treatment.Bioengineering (Basel, Switzerland) · 2024Article
- Flow Diverter Performance for the Treatment of Intracranial Aneurysms: An International Multicenter Comparative Study.Stroke (Hoboken, N.J.) · 2023Article
- First multicenter experience using the Silk Vista flow diverter in 60 consecutive intracranial aneurysms: technical aspects.Journal of neurointerventional surgery · 2021Article
- Further Development of Combined Techniques Using Stent Retrievers, Aspiration Catheters and BGC : The PROTECTClinical neuroradiology · 2020Article
- Filament inadequate wall apposition of the different ends of flow diverters in the abdominal aorta of rabbits.The neuroradiology journal · 2020Article
- Placement of a Stent within a Flow Diverter Improves Aneurysm Occlusion Rates.AJNR. American journal of neuroradiology · 2019Article
- Acute thrombus formation on phosphorilcholine surface modified flow diverters.Journal of neurointerventional surgery · 2018Article
- The Exchange-Free Technique: A Novel Technique for Enhancing Surpass Flow Diverter Placement.Asian journal of neurosurgeryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Flow diverter (FD) malapposition is associated with stroke-related complications. We document the use of self-expanding nitinol stents to remove/reduce the ledge of a FD deployed for aneurysm treatment. Methods We identified five patients who were treated with the Pipeline embolization device (PED) in conjunction with a Neuroform EZ stent for inadequate wall apposition of the ends of the FD at our institution between May 2014 and July 2015. Among other parameters, angiographic results, cone-beam computed tomography assessment of wall apposition and patient clinical outcome were evaluated. Results Incomplete device end apposition was seen in three cases, and precarious positioning of the distal end of the PED over the aneurysm neck was seen in two cases. In all five cases, successful treatment with good wall apposition and proper pinning of the PED distal edge was achieved using an additional Neuroform EZ stent. Appropriate aneurysm neck coverage and flow stagnation was seen in all cases. The combination of high radial outward force and open-cell design permits the Neuroform EZ stent to jail the malappositioned edges of the FD while maintaining good vessel-wall apposition itself and prevent migration of the PED. Short-term follow-up angiography showed device patency and complete aneurysm obliteration in all cases. Conclusions Preliminary results of this small case series suggest that the Neuroform EZ stent allows for effective treatment of FD malapposition in selected patients amenable for this endovascular approach. Long-term and larger cohort studies are needed to validate these results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials