Evidence map›Paper›PMID 27929049›Full record

ArticleScientific reports2016

Development of a Fiber Laser with Independently Adjustable Properties for Optical Resolution Photoacoustic Microscopy.

Esra Aytac-Kipergil, Aytac Demirkiran, Nasire Uluc, Seydi Yavas, Tunc Kayikcioglu, Sarper Salman, Sohret Gorkem Karamuk, Fatih Omer Ilday, Mehmet Burcin Unlu

Abstract read
In one paragraph

Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Article
  3. Efficient label-freePhotoacoustics · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Esra Aytac-KipergilDepartment of Physics, Bogazici University, 34342, Istanbul, Turkey.
Aytac DemirkiranDepartment of Physics, Bogazici University, 34342, Istanbul, Turkey.
Nasire UlucDepartment of Physics, Bogazici University, 34342, Istanbul, Turkey.
Seydi YavasInstitute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey.
Tunc KayikciogluDepartment of Physics, Bogazici University, 34342, Istanbul, Turkey.
Sarper SalmanFiberLAST, Inc., 06800, Ankara, Turkey.
Sohret Gorkem KaramukDepartment of Electrical and Electronics Engineering, Bilkent University, 06800, Ankara, Turkey.
Fatih Omer IldayDepartment of Electrical and Electronics Engineering, Bilkent University, 06800, Ankara, Turkey.
Mehmet Burcin UnluDepartment of Physics, Bogazici University, 34342, Istanbul, Turkey.

Funding

European Research Council 617521
6 · The paper itself

Abstract

Photoacoustic imaging is based on the detection of generated acoustic waves through thermal expansion of tissue illuminated by short laser pulses. Fiber lasers as an excitation source for photoacoustic imaging have recently been preferred for their high repetition frequencies. Here, we report a unique fiber laser developed specifically for multiwavelength photoacoustic microscopy system. The laser is custom-made for maximum flexibility in adjustment of its parameters; pulse duration (5-10 ns), pulse energy (up to 10 μJ) and repetition frequency (up to 1 MHz) independently from each other and covers a broad spectral region from 450 to 1100 nm and also can emit wavelengths of 532, 355, and 266 nm. The laser system consists of a master oscillator power amplifier, seeding two stages; supercontinuum and harmonic generation units. The laser is outstanding since the oscillator, amplifier and supercontinuum generation parts are all-fiber integrated with custom-developed electronics and software. To demonstrate the feasibility of the system, the images of several elements of standardized resolution test chart are acquired at multiple wavelengths. The lateral resolution of optical resolution photoacoustic microscopy system is determined as 2.68 μm. The developed system may pave the way for spectroscopic photoacoustic microscopy applications via widely tunable fiber laser technologies.

Identifiers

PMID27929049
PMCPMC5144145

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.