Evidence map›Paper›PMID 27927235›Full record

ArticleRadiation oncology (London, England)2016

Stereoscopic X-ray imaging, cone beam CT, and couch positioning in stereotactic radiotherapy of intracranial tumors: preliminary results from a cross-modality pilot installation.

Barbara Zollner, Christian Heinz, Sabrina Pitzler, Farkhad Manapov, Steffi Kantz, Maya Christine Rottler, Maximilian Niyazi, Ute Ganswindt, Claus Belka, Hendrik Ballhausen

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Positioning error analysis of the fraxion localization system in the intracranial stereotactic radiotherapy of tumors.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2021
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Barbara ZollnerLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Christian HeinzLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Sabrina PitzlerLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Farkhad ManapovLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Steffi KantzLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Maya Christine RottlerLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Maximilian NiyaziLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Ute GanswindtLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Claus BelkaLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany.
Hendrik BallhausenLMU Munich, Department of Radiation Oncology, Marchioninistraße 15, Munich, 81377, Germany. Hendrik.Ballhausen@med.uni-muenchen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo assess the accuracy and precision of a fully integrated pilot installation of stereoscopic X-ray imaging and kV-CBCT for automatic couch positioning in stereotactic radiotherapy of intracranial tumors. Positioning errors as detected by stereoscopic X-ray imaging are compared to those by kV-CBCT (i.e. the accuracy of the new method is verified by the established method), and repeated X-ray images are compared (i.e. the precision of new method is determined intra-modally).

methodsPreliminary results are reported from a study with 32 patients with intracranial tumors. Patients were treated with stereotactic radiotherapy guided by stereoscopic X-ray imaging and kV-CBCT. Patient positioning was automatically corrected by a robotic couch. Cross-modal discrepancies in position detection were measured (N = 42). Intra-modal improvements after correction and re-verification by stereoscopic X-ray imaging were measured (N = 70). The accuracy and precision of stereoscopic X-ray imaging and the accuracy and precision of CBCT were confirmed in phantom measurements (N = 12 shifts of a ball bearing phantom, N = 24 shifts of a head phantom).

resultsAfter correction based on stereoscopic X-ray imaging 95% of residual mean errors were below 0.4, 0.4, 0.5, and 0.7 mm (lateral, longitudinal, vertical, radial, respectively). Stereoscopic X-ray imaging and CBCT were in close agreement with an average discrepancy of 0.1, 0.5, 0.3 and 0.8 mm, respectively. 95% of discrepancies were below 0.8, 1.2, 1.0, and 1.4 mm, respectively. After correction and re-verification by stereoscopic X-ray imaging, the remaining intra-modal residual error was consistent with zero (p = 0.31, p = 0.48, p = 0.81 in lateral, longitudinal, and vertical direction; p-values from two-tailed t-test). The inherent technical accuracy and precision of stereoscopic X-ray imaging and the accuracy and precision of CBCT were found to be of the order of 0.1 mm in controlled phantom settings.

conclusionsIn a routine clinical setting, both stereoscopic X-ray imaging and CBCT were able to reduce positioning errors by an order of magnitude. The end-to-end precision of the system, measured from the discrepancy (mean) between ExacTrac and CBCT, in a clinical setting seems to be about 0.8 mm radially, including couch positioning. The precision (measured from repeatability of ExacTrac, intra-modal) was found to be about 0.7 mm radially in a clinical setting.

Indexed as

AdultAgedAged, 80 and overBrain NeoplasmsCone-Beam Computed TomographyFemaleHumansMaleMiddle AgedPatient PositioningRadiographyRadiosurgeryRadiotherapy Planning, Computer-AssistedRetrospective StudiesCone beam computed tomographyImage guided radiotherapyIntracranial tumorsPatient positioningRadiosurgeryStereoscopic X-ray imagingStereotactic radiotherapy

Identifiers

PMID27927235
PMCPMC5142336

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.