ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)
Ventricular Assist Device Implantation Configurations Impact Overall Mechanical Circulatory Support System Thrombogenic Potential.
Article in ASAIO journal (American Society for Artificial Internal Organs : 1992). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 17 citations in OpenAlex.
- [Design of a benchmark pump model and optimization of hemolysis testing protocol for evaluation of blood pump hemocompatibility].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026Article
- A Computational Investigation of the Effects of Temporal Synchronization of Left Ventricular Assist Device Speed Modulation with the Cardiac Cycle on Intraventricular Hemodynamics.Annals of biomedical engineering · 2024Article
- Resistance valves in circulatory loops have a significant impact onFrontiers in physiology · 2023Article
- Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.Artificial organs · 2020Article
- New Insights into Valve Hemodynamics.Rambam Maimonides medical journal · 2020Review
- Prothrombotic activity of cytokine-activated endothelial cells and shear-activated platelets in the setting of ventricular assist device support.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2019Article
- Device Thrombogenicity Emulation: An In Silico Predictor of In Vitro and In Vivo Ventricular Assist Device Thrombogenicity.Scientific reports · 2019Article
- Principles of TAVR valve design, modelling, and testing.Expert review of medical devices · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
Ventricular assist devices (VADs) became in recent years the standard of care therapy for advanced heart failure with hemodynamic compromise. With the steadily growing population of device recipients, various postimplant complications have been reported, mostly associated with the hypershear generated by VADs that enhance their thrombogenicity by activating platelets. Although VAD design optimization can significantly improve its thromboresistance, the implanted VAD need to be evaluated as part of a system. Several clinical studies indicated that variability in implantation configurations may contribute to the overall system thrombogenicity. Numerical simulations were conducted in the HeartAssist 5 (HA5) and HeartMate II (HMII) VADs in the following implantation configurations: 1) inflow cannula angles: 115° and 140° (HA5); 2) three VAD circumferential orientations: 0°, 30°, and 60° (HA5 and HMII); and 3) 60° and 90° outflow graft anastomotic angles with respect to the ascending aorta (HA5). The stress accumulation of the platelets was calculated along flow trajectories and collapsed into a probability density function, representing the "thrombogenic footprint" of each configuration-a proxy to its thrombogenic potential (TP). The 140° HA5 cannula generated lower TP independent of the circumferential orientation of the VAD. Sixty-degree orientation generated the lowest TP for the HA5 versus 0° for the HMII. An anastomotic angle of 60° resulted in lower TP for HA5. These results demonstrate that optimizing the implantation configuration reduces the overall system TP. Thromboresistance can be enhanced by combining VAD design optimization with the surgical implantation configurations for achieving better clinical outcomes of implanted VADs.