Ventricular Assist Device Implantation Configurations Impact Overall Mechanical Circulatory Support System Thrombogenic Potential.

Wei-Che Chiu, Yared Alemu, Allison J McLarty, Shmuel Einav, Marvin J Slepian, Danny Bluestein

Abstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. [Design of a benchmark pump model and optimization of hemolysis testing protocol for evaluation of blood pump hemocompatibility].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. New Insights into Valve Hemodynamics.Rambam Maimonides medical journal · 2020
    Review
  6. Prothrombotic activity of cytokine-activated endothelial cells and shear-activated platelets in the setting of ventricular assist device support.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2019
    Article
  7. Article
  8. Principles of TAVR valve design, modelling, and testing.Expert review of medical devices · 2018
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Wei-Che ChiuFrom the *Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York; †Department of Surgery, Stony Brook University, Stony Brook, New York; and ‡Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, Arizona.
Yared Alemu
Allison J McLarty
Shmuel Einav
Marvin J Slepian
Danny Bluestein
Stony Brook University · US

Funding

Optimizing Cardiovascular Device Thromboresistance for Eliminating AnticoagulantsU01EB012487 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2010 to 2014
$6.9M
Multiscale Modeling of Blood Flow and Platelet Mediated ThrombosisU01HL131052 · NHLBI · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2016 to 2020
$3.6M
Optimizing Cardiovascular Devices Thrombogenicity for Eliminating AnticoagulationR01EB008004 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2007 to 2009
$1.7M
NHLBI NIH HHS U01 HL131052NIBIB NIH HHS R01 EB008004NIBIB NIH HHS U01 EB012487
6 · The paper itself

Abstract

Ventricular assist devices (VADs) became in recent years the standard of care therapy for advanced heart failure with hemodynamic compromise. With the steadily growing population of device recipients, various postimplant complications have been reported, mostly associated with the hypershear generated by VADs that enhance their thrombogenicity by activating platelets. Although VAD design optimization can significantly improve its thromboresistance, the implanted VAD need to be evaluated as part of a system. Several clinical studies indicated that variability in implantation configurations may contribute to the overall system thrombogenicity. Numerical simulations were conducted in the HeartAssist 5 (HA5) and HeartMate II (HMII) VADs in the following implantation configurations: 1) inflow cannula angles: 115° and 140° (HA5); 2) three VAD circumferential orientations: 0°, 30°, and 60° (HA5 and HMII); and 3) 60° and 90° outflow graft anastomotic angles with respect to the ascending aorta (HA5). The stress accumulation of the platelets was calculated along flow trajectories and collapsed into a probability density function, representing the "thrombogenic footprint" of each configuration-a proxy to its thrombogenic potential (TP). The 140° HA5 cannula generated lower TP independent of the circumferential orientation of the VAD. Sixty-degree orientation generated the lowest TP for the HA5 versus 0° for the HMII. An anastomotic angle of 60° resulted in lower TP for HA5. These results demonstrate that optimizing the implantation configuration reduces the overall system TP. Thromboresistance can be enhanced by combining VAD design optimization with the surgical implantation configurations for achieving better clinical outcomes of implanted VADs.

Indexed as

CatheterizationHeart-Assist DevicesHeart FailureHumansThrombosis

Identifiers

PMID27922885
PMCPMC5411323
OpenAlexW2559940191

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.