Evidence map›Paper›PMID 27921069›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2016

Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers.

Sun Il Kwon, Alessandro Ferri, Alberto Gola, Eric Berg, Claudio Piemonte, Simon R Cherry, Emilie Roncali

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sun Il KwonUniversity of California Davis , Department of Biomedical Engineering, Davis, California 95616, United States.
Alessandro FerriFondazione Bruno Kessler , via Sommarive 18, Trento, Italy.
Alberto GolaFondazione Bruno Kessler , via Sommarive 18, Trento, Italy.
Eric BergUniversity of California Davis , Department of Biomedical Engineering, Davis, California 95616, United States.
Claudio PiemonteFondazione Bruno Kessler , via Sommarive 18, Trento, Italy.
Simon R CherryUniversity of California Davis , Department of Biomedical Engineering, Davis, California 95616, United States.
Emilie RoncaliUniversity of California Davis , Department of Biomedical Engineering, Davis, California 95616, United States.

Funding

EXPLORER: Changing the Molecular Imaging Paradigm with Total Body PETR01CA206187 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI BADAWI, RAMSEY D., CHERRY, SIMON R · 2015 to 2019
$15.5M
Innovative Silicon Photomultiplier Technologies for Small-Animal PETR01EB019439 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R · 2015 to 2018
$1.4M
NCI NIH HHS R01 CA206187NIBIB NIH HHS R01 EB019439
6 · The paper itself

Abstract

Current research in the field of positron emission tomography (PET) focuses on improving the sensitivity of the scanner with thicker detectors, extended axial field-of-view, and time-of-flight (TOF) capability. These create the need for depth-of-interaction (DOI) encoding to correct parallax errors. We have proposed a method to encode DOI using phosphor-coated crystals. Our initial work using photomultiplier tubes (PMTs) demonstrated the possibilities of the proposed method, however, a major limitation of PMTs for this application is poor quantum efficiency in yellow light, corresponding to the wavelengths of the converted light by the phosphor coating. In contrast, the red-green-blue-high-density (RGB-HD) silicon photomultipliers (SiPMs) have a high photon detection efficiency across the visible spectrum. Excellent coincidence resolving time (CRT; [Formula: see text]) was obtained by coupling RGB-HD SiPMs and [Formula: see text] lutetium fine silicate crystals coated on a third of one of their lateral sides. Events were classified in three DOI bins ([Formula: see text] width) with an average sensitivity of 83.1%. A CRT of [Formula: see text] combined with robust DOI encoding is a marked improvement in the phosphor-coated approach that we pioneered. For the first time, we read out these crystals with SiPMs and clearly demonstrated the potential of the RGB-HD SiPMs for this TOF-DOI PET detector.

Indexed as

coincidence timing resolutiondepth-of-interactionphosphor coatingpositron emission tomographysilicon photomultipliertime-of-flight

Identifiers

PMID27921069
PMCPMC5120149

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.