ArticleJournal of medical imaging (Bellingham, Wash.)2016
Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers.
Article in Journal of medical imaging (Bellingham, Wash.), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Design and proof of concept of a double-panel TOF-PET system.EJNMMI physics · 2024Article
- The quest for multifunctional and dedicated PET instrumentation with irregular geometries.Annals of nuclear medicine · 2024Review
- High resolution detectors for whole-body PET scanners by using dual-ended readout.EJNMMI physics · 2022Article
- Optimization of scintillator-reflector optical interfaces for the LUT Davis model.Medical physics · 2021Article
- Time of Flight in Perspective: Instrumental and Computational Aspects of Time Resolution in Positron Emission Tomography.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Small animal PET: a review of what we have done and where we are going.Physics in medicine and biology · 2020Review
- Optimizing sensitivity and dynamic range of silicon photomultipliers for frequency-domain near infrared spectroscopy.Biomedical optics express · 2020Article
- Innovations in Instrumentation for Positron Emission Tomography.Seminars in nuclear medicine · 2018Review
- An integrated model of scintillator-reflector properties for advanced simulations of optical transport.Physics in medicine and biology · 2017Article
- Advanced optical simulation of scintillation detectors in GATE V8.0: first implementation of a reflectance model based on measured data.Physics in medicine and biology · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Current research in the field of positron emission tomography (PET) focuses on improving the sensitivity of the scanner with thicker detectors, extended axial field-of-view, and time-of-flight (TOF) capability. These create the need for depth-of-interaction (DOI) encoding to correct parallax errors. We have proposed a method to encode DOI using phosphor-coated crystals. Our initial work using photomultiplier tubes (PMTs) demonstrated the possibilities of the proposed method, however, a major limitation of PMTs for this application is poor quantum efficiency in yellow light, corresponding to the wavelengths of the converted light by the phosphor coating. In contrast, the red-green-blue-high-density (RGB-HD) silicon photomultipliers (SiPMs) have a high photon detection efficiency across the visible spectrum. Excellent coincidence resolving time (CRT; [Formula: see text]) was obtained by coupling RGB-HD SiPMs and [Formula: see text] lutetium fine silicate crystals coated on a third of one of their lateral sides. Events were classified in three DOI bins ([Formula: see text] width) with an average sensitivity of 83.1%. A CRT of [Formula: see text] combined with robust DOI encoding is a marked improvement in the phosphor-coated approach that we pioneered. For the first time, we read out these crystals with SiPMs and clearly demonstrated the potential of the RGB-HD SiPMs for this TOF-DOI PET detector.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.