ReviewJournal of atrial fibrillation
Contact Force and Atrial Fibrillation Ablation.
Review in Journal of atrial fibrillation. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Very low tidal volume, high-frequency ventilation in atrial fibrillation ablation: a systematic review.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022Pooled it
- The Integral Role of Cardiac Imaging in the Electrophysiology Field.The Journal of innovations in cardiac rhythm management · 2025Review
- Instant variable stiffness in cardiovascular catheters based on fiber jamming.Science advances · 2025Article
- Linear Ablation Using a Contact Force-Sensing Catheter in Ablation for Persistent Atrial Fibrillation: A Prospective Randomized Trial.Journal of clinical medicine · 2024Article
- The Feasibility, Safety and Outcome of Very High-Power Short Duration Radiofrequency Ablation in Pulmonary Vein Isolation: A Real-World Observation Study.Reviews in cardiovascular medicine · 2024Article
- Fast-Response Variable-Stiffness Magnetic Catheters for Minimally Invasive Surgery.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
- Catheter Ablation Approaches for the Treatment of Arrhythmia Recurrence in Patients with a Durable Pulmonary Vein IsolationBalkan medical journal · 2023Review
- Impact of Contact Force-Sensing Catheters on Fluoroscopy Time in Interventional Electrophysiology: A European Survey.Journal of clinical medicine · 2022Article
- The impact of steerable sheaths on unblinded contact force during catheter ablation for atrial fibrillation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2020Article
- The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.Arrhythmia & electrophysiology review · 2018Review
- Use of Intraprocedural Ibutilide During Stepwise Ablation of Long-Standing Persistent Atrial Fibrillation.Journal of atrial fibrillation · 2018Article
- Pulmonary vein isolation for atrial fibrillation: Does ablation technique influence outcome?Indian heart journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Catheters able to measure the force and vector of contact between the catheter tip and myocardium are now available. Pre-clinical work has established that the degree of contact between the radiofrequency ablation catheter and myocardium correlates with the size of the delivered lesion. Excess contact is associated with steam pops and perforation. Catheter contact varies within the left atrium secondary to factors including respiration, location, atrial rhythm and the trans-septal catheter delivery technology used. Compared with procedures performed without contact force (CF)-sensing, the use of this technology has, in some studies, been found to improve complication rates, procedure and fluoroscopy times, and success rates. However, for each of these parameters there are also studies suggesting a lack of difference from the availability of CF data. Nevertheless, CF-sensing technology has been adopted as a standard of care in many institutions. It is likely that use of CF-sensing technology will allow for the optimization of each individual radiofrequency application to maximize efficacy and procedural safety. Recent work has attempted to define what these optimal targets should be, and approaches to do this include assessing for sites of pulmonary vein reconnection after ablation, or comparing the impedance response to ablation. Based on such work, it is apparent that factors including mean CF, force time integral (the area under the force-time curve) and contact stability are important determinants of ablation efficacy. Multicenter prospective randomized data are lacking in this field and required to define the CF parameters required to produce optimal ablation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials