Design of a dual-resolution collimator for preclinical cardiac SPECT with a stationary triple-detector system.

Stephen C Moore, Mi-Ae Park, Zhe Liu, Morgan C Lyon, Lindsay C Johnson, Victor H Lushear, James G Westberg, Scott D Metzler

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Stephen C MooreDepartment of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115.
Mi-Ae ParkDepartment of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115.
Zhe LiuDepartment of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115.
Morgan C LyoninviCRO, LLC, Boston, Massachusetts 02210.
Lindsay C JohnsonDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104.
Victor H LushearSolidscape, Inc., Merrimack, New Hampshire 03054.
James G WestbergSolidscape, Inc., Merrimack, New Hampshire 03054.
Scott D MetzlerDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104.
Brigham and Women's Hospital · USUniversity of Pennsylvania · USHarvard University · USInvicro (United States) · US

Funding

Multidisciplinary Training in Cardiovascular BiologyT32HL007954 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI DAVIES, PETER FRANCIS · 2000 to 2019
$9.9M
Preclinical cardiac imaging package for clinical SPECT systemsR01HL111883 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI METZLER, SCOTT DEAN, MOORE, STEPHEN C. · 2012 to 2015
$2.8M
NHLBI NIH HHS R01 HL111883NHLBI NIH HHS T32 HL007954
6 · The paper itself

Abstract

purposeOne approach to preclinical single-photon emission computed tomography (SPECT) imaging that provides both high resolution and high sensitivity is based on imaging a mouse inside a collimating tube; many magnified pinhole projection images from a small target region, e.g., the heart, can be recorded simultaneously on multiple detectors with little multiplexing since each pinhole aperture's opening angle is restricted to view mostly the target organ. However, to obtain complete data for reconstruction, it may be necessary to scan the mouse through the target region of the tube. The authors are developing a different approach based on acquisition and reconstruction of both low-resolution and high-resolution projection data acquired sequentially through many pinholes embedded in two tungsten tube sections of different diameters, a "scout" section and a high-resolution section, placed end-to-end along the axis of a triple-head clinical SPECT scanner. This paper describes the design procedures used to determine the geometric parameters of two new collimator-tube sections, as well as one approach for joint reconstruction of data acquired from both sections.

methodsThe high-resolution section was designed by projecting as many pinhole views of a simulated mouse heart as possible over each detector's camera, with no overlapping of heart projections and minimal overlapping between adjacent "hot" organ and cardiac projections. The authors then jointly optimized the geometric design of the scout section for a triple-detector camera system, as well as the number of maximum-likelihood expectation maximization (MLEM) iterations required to provide minimum mean-squared error of reconstructed voxel counts throughout a 7-cm axial range, with the constraints of fixed, 2.4-mm scout system resolution at the tube center for all apertures, limited multiplexing, and no detector motion. Simulated mouse projection data from both tube sections were then reconstructed to illustrate a simple approach for using high-resolution data to improve the whole-body scout images within a cylindrical region surrounding the heart.

resultsThe 2-cm-inner-radius high-resolution tube section accommodated 87 platinum-iridium pinhole inserts, each with a 0.3-mm square aperture; their radial distances from the centerline of the system ranged from 2.2 to 3.0 cm. The optimal radial distance to the closest scout pinhole and optimal number of MLEM iterations were 4.4 cm and 35 iterations, respectively, and the radial distances of the 39 scout pinholes ranged from 4.4 to 4.8 cm; aperture sizes ranged from 1.1 to 1.7 mm transaxially and 0.9-1.5 mm axially. After including data from the high-resolution section viewing the heart region into whole-body mouse reconstructions from scout data, the authors obtained high-resolution images of the heart, embedded within lower resolution images of the body, with minimal artifacts.

conclusionsThe authors have optimized a dual-resolution collimator tube that provides both whole-body projections of a mouse and more targeted projections centered on the heart that can be jointly reconstructed to obtain high-resolution images of the heart embedded within lower-resolution whole-body images.

Indexed as

AnimalsEquipment DesignHeartImage Processing, Computer-AssistedMiceTomography, Emission-Computed, Single-Photon

Identifiers

PMID27908172
PMCPMC5097051
OpenAlexW2548151721

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.