Evidence map›Paper›PMID 27896599›Full record

ArticleJournal of materials science. Materials in medicine2017

Inflammatory cell response to ultra-thin amorphous and crystalline hydroxyapatite surfaces.

Louise Rydén, Omar Omar, Anna Johansson, Ryo Jimbo, Anders Palmquist, Peter Thomsen

Open access · hybridAbstract read
In one paragraph

Article in Journal of materials science. Materials in medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 40 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Louise RydénDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden.
Omar OmarDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden. omar.omar@biomaterials.gu.se.ORCID http://orcid.org/0000-0002-2610-1294
Anna JohanssonDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden.
Ryo JimboDepartment of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Malmö, Sweden.
Anders PalmquistDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden.
Peter ThomsenDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden.
University of Gothenburg · SEBioMar (Norway) · NOMalmö University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It has been suggested that surface modification with a thin hydroxyapatite (HA) coating enhances the osseointegration of titanium implants. However, there is insufficient information about the biological processes involved in the HA-induced response. This study aimed to investigate the inflammatory cell response to titanium implants with either amorphous or crystalline thin HA. Human mononuclear cells were cultured on titanium discs with a machined surface or with a thin, 0.1 μm, amorphous or crystalline HA coating. Cells were cultured for 24 and 96 h, with and without lipopolysaccharide (LPS) stimulation. The surfaces were characterized with respect to chemistry, phase composition, wettability and topography. Biological analyses included the percentage of implant-adherent cells and the secretion of pro-inflammatory cytokine (TNF-α) and growth factors (BMP-2 and TGF-β1). Crystalline HA revealed a smooth surface, whereas the amorphous HA displayed a porous structure, at nano-scale, and a hydrophobic surface. Higher TNF-α secretion and a higher ratio of adherent cells were demonstrated for the amorphous HA compared with the crystalline HA. TGF-β1 secretion was detected in all groups, but without any difference. No BMP-2 secretion was detected in any of the groups. The addition of LPS resulted in a significant increase in TNF-α in all groups, whereas TGF-β1 was not affected. Taken together, the results show that thin HA coatings with similar micro-roughness but a different phase composition, nano-scale roughness and wettability are associated with different monocyte responses. In the absence of strong inflammatory stimuli, crystalline hydroxyapatite elicits a lower inflammatory response compared with amorphous hydroxyapatite.

Indexed as

Dental ImplantsInflammationAnimalsBone Morphogenetic Protein 2Cell LineCoated Materials, BiocompatibleCrystallizationCytokinesDurapatiteEnzyme-Linked Immunosorbent AssayHumansLeukocytes, MononuclearLipopolysaccharidesMaterials TestingMiceMonocytesBMP2 protein, humanBone Morphogenetic Protein 2Coated Materials, BiocompatibleCytokinesDental ImplantsDurapatiteLipopolysaccharidesTitaniumTransforming Growth Factor beta1Tumor Necrosis Factor-alpha

Identifiers

PMID27896599
PMCPMC5126180
OpenAlexW2557664923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.