Evidence map›Paper›PMID 27895544›Full record

ArticleClinical proteomics2016

Mesoporous silica chip: enabled peptide profiling as an effective platform for controlling bio-sample quality and optimizing handling procedure.

Kai Liang, Hongmei Wu, Tony Y Hu, Yan Li

Abstract read
In one paragraph

Article in Clinical proteomics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kai LiangLaboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101 China.
Hongmei WuLaboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101 China ; GuangDong Bio-healtech Advanced Co., Ltd, Foshan City, 52800 GuangDong Province China.
Tony Y HuDepartment of Nanomedicine, The Methodist Hospital Research Institute, Houston, TX 77030 USA ; Department of Cell and Developmental Biology, Weill Cornell Medical College of Cornell University, 445 E. 69th Street, New York, NY 10021 USA.
Yan LiLaboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101 China.

Funding

Direct quantitation of the circulating Mtb-peptidome for pediatric TB managementR01HD090927 · NICHD · TULANE UNIVERSITY OF LOUISIANA · PI Christopher J Lyon, Charles DeBeaux Mitchell · 2017 to 2026
$4.5M
Quantification of Circulating Antigens for Pediatric TB Diagnosis andTreatment MonitoringR01AI122932 · NIAID · METHODIST HOSPITAL RESEARCH INSTITUTE · PI HU, TONY Y. · 2016 to 2019
$1.8M
Real-time Detection of Active TB in HIV Exposed Children on CustomizedNanotrapR01AI113725 · NIAID · METHODIST HOSPITAL RESEARCH INSTITUTE · PI LABAER, JOSHUA · 2015 to 2018
$1.6M
Multiplexed quantification of circulating peptidomic signatures for EBOLA early diagnosisR21AI126361 · NIAID · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI LABAER, JOSHUA · 2017 to 2018
$373k
NIAID NIH HHS R01 AI113725NIAID NIH HHS R01 AI122932NICHD NIH HHS R01 HD090927
6 · The paper itself

Abstract

backgroundHigh quality clinical samples are critical for meaningful interpretation of data obtained in both basic and translational medicine. More specifically, optimized pre-analysis handling to bio-sample is crucial for avoiding biased analysis in a clinical setting. A universally applicable method for the evaluation of sample quality and pre-analysis handling is therefore in great demand.

methodsThe fingerprint pattern of low molecular weight (LMW) peptides in sera is directly associated with sample quality and handling process. Previous studies for enrichment/isolation of LMW peptides have shown that LMW peptides can be enriched by silica meso-porous material in a sensitive and high-throughput manner. Here, a peptide profile approach utilizing mesoporous silica chip-based sample preparation combined with MALDI MS analysis was used as a new platform for evaluation of bio-sample quality. Rat sera were selected as model sample and analyzed according to their LMW peptide fingerprint spectra.

resultsThis novel method can complete the entire sample preparation procedure in a short period of time (<40 min), requires minimum amounts of sample (<10 µL), is of high sensitivity (LOD 10 ng/mL) as well as high reproducibility (CV% < 15%). According to the acquired LMW peptide spectra, we were able to distinguish the serum samples processed under different conditions (including different storage temperature, time, and freezing/thaw cycles) with the help of bioinformatics tools (principle composition analysis and significant difference analysis), and identify the samples that had significantly changed due to the inappropriate processing. Based on the percentage of significantly changed peaks in LMW peptide mass spectrum after handling, a judgment standard was established that can be used to evaluate the status of preservation of a biological sample. In addition, our principle study established recommendations for storage time, storage temperature and freeze/thaw conditions.

conclusionOur novel method for analysis of bio-samples allows for effective identification of variations in composition within samples, and provides a cost-effective tool for simple sample manipulation in a clinical setting.

Indexed as

LMW peptideMALDI MSPre-analysis handlingSample qualitySilica mesoporous material

Identifiers

PMID27895544
PMCPMC5120552

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.