Trial reportHernia : the journal of hernias and abdominal wall surgery2017
Randomized trial comparing self gripping semi re-absorbable mesh (PROGRIP) with polypropylene mesh in open inguinal hernioplasty: the 6 years result.
Trial report in Hernia : the journal of hernias and abdominal wall surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 16 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Randomized Study of Self Gripping Semi-resorbable Mesh (PROGRIP) With Polypropylene Mesh in Open Inguinal Hernia Repair - the 6 Years Result
Use of Pre-peritoneal Drainage in rTAPP - a Comparative Study With Laparoscopic TEP
Who cites it
16 citing papers in PubMed, 5 syntheses or guidelines pooled it.
- Post operative pain associated with ProGrip mesh hernioplasty: a systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2024Pooled it
- Comparison of outcomes of ventral hernia repair using different meshes: a systematic review and network meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2022Pooled it
- Suture fixation versus self-gripping mesh for open inguinal hernia repair: a systematic review with meta-analysis and trial sequential analysis.Surgical endoscopy · 2021Pooled it
- Meta-analysis of postoperative pain using non-sutured or sutured single-layer open mesh repair for inguinal hernia.BJS open · 2019Pooled it
- Open Inguinal Hernia Repair: A Network Meta-analysis Comparing Self-Gripping Mesh, Suture Fixation, and Glue Fixation.World journal of surgery · 2019Pooled it
- Self-fixating (sutureless) mesh versus sutured polypropylene mesh in open Lichtenstein repair: a participant-blinded randomized trial.Hernia : the journal of hernias and abdominal wall surgery · 2026Trial
- Progrip versus ProFlor: two fixation-free devices for laparoscopic inguinal hernia repair-the Pro/Pro study, a randomized clinical trial.Surgical endoscopy · 2025Trial
- Long-term results of the SOFTGRIP trial: TIPP versus ProGrip Lichtenstein's inguinal hernia repair.Hernia : the journal of hernias and abdominal wall surgery · 2023Trial
- Does the use of monopolar energy as the preferred mode of dissection effectively reduce seroma formation in laparoscopic total extra peritoneal hernioplasty? A prospective double-blinded randomized control trial.Hernia : the journal of hernias and abdominal wall surgery · 2020Trial
- Preperitoneal closed-system suction drainage after totally extraperitoneal hernioplasty in the prevention of early seroma formation: a prospective double-blind randomised controlled trial.Hernia : the journal of hernias and abdominal wall surgery · 2018Trial
- Self-gripping mesh in laparoscopic inguinal hernia repair: A comparative study about surgical time, post-operative pain and recurrence.Journal of minimal access surgery · 2025Article
- Comprehensive systematic review on the self-gripping mesh vs sutured mesh in inguinal hernia repair.Surgery open science · 2024Review
- Impact of COVID-19 on clinical outcomes of robotic inguinal hernia repair.Hernia : the journal of hernias and abdominal wall surgery · 2023Article
- Does the mesh type influence the outcomes and costs of robotic inguinal hernia repair?Journal of robotic surgery · 2023Article
- Seroma after TEP, preventable or not? Author's reply.Hernia : the journal of hernias and abdominal wall surgery · 2021Article
- Comparison between self-gripping, semi re-absorbable meshes with polyethylene meshes in Lichtenstein, tension-free hernia repair: preliminary results from a single center.Acta bio-medica : Atenei Parmensis · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe use of absorbable polylactic acid hook self-gripping polypropylene mesh in open inguinal hernia may potentially reduce operative time and enhance patient recovery. The objective of this randomized trial is to compare the outcomes following self-gripping mesh repair to polypropylene mesh secured with sutures in open inguinal hernioplasty.
methodEligible patients aged 18-80 years old, who had primary unilateral uncomplicated inguinal hernia, were randomized into either Polypropylene (PL) group or PROGRIP (PG) group just before the placement of mesh intra-operatively by computer generated code. The primary outcome was the time from mesh placement to end of operation, whereas secondary outcomes included the total operative time, amount of analgesic used, length of post-operative stay, seroma formation, chronic discomfort, chronic pain score and recurrence. The study has been registered in http://www.clinicaltrial.gov carrying an ID of NCT00960011. Patients were followed-up in outpatient clinic for up to 6 years after operation.
resultsFrom March 2009 to April 2016, 45 patients were included. The mean age of PG group (n = 22) was 62.0 ± 15.7 years old while that of the PL group was 62.6 ± 4.9 years old (n = 23). There was no significant difference regarding the smoking habit, drinking habit, comorbidities, previous hernia operation and Nyhus type of hernia between the two groups. The size of defects, the time of groin dissection and the size of incision were similar. In the PG group, there was significant reduction in the time for mesh placement (11.8 ± 3.1 vs. 21.0 ± 6.2 min, p < 0.001) and total operative time (39.2 ± 9.8 vs. 47.7 ± 8.0 min, p = 0.003). There was one recurrence in PL group and nil in PG group. Although there was a significant difference in paresthesia between 2 groups after operation, the difference disappears with time and comparable from post-operative 1 year onwards. There was no difference in chronic pain, chronic discomfort, affect daily activities, palpable mesh demonstrated throughout the whole study period till 6 years after operation.
conclusionsThe use of polylactic acid self-gripping mesh in open inguinal hernia repair effectively reduces the operating time with comparable long-term surgical outcome with traditional polypropylene mesh.
Indexed as
Identifiers
27889845What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.