Manual versus Automated moNitoring Accuracy of GlucosE II (MANAGE II).

Cláudia Righy Shinotsuka, Alexandre Brasseur, David Fagnoul, Timothy So, Jean-Louis Vincent, Jean-Charles Preiser

Registry-linked trialAbstract readComparative Study
In one paragraph

Article in Critical care (London, England), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01720381 (Manual vs. Automated moNitoring Accuracy of GlucosE II), which is not on this map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01720381 completednot on this map

Manual vs. Automated moNitoring Accuracy of GlucosE II (MANAGE II)

TypeobservationalSponsorOptiScan Biomedical CorporationRan2012 to 2014Enrolled98ConditionsHyperglycemia
3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Article
  3. Article
  4. Continuous Glucose Monitoring in the Hospital.Endocrinology and metabolism (Seoul, Korea) · 2021
    Review
  5. Review
  6. Accuracy of Blood Glucose Measurement and Blood Glucose Targets.Journal of diabetes science and technology · 2020
    Review
  7. Review
  8. Glucose Management Technologies for the Critically Ill.Journal of diabetes science and technology · 2019
    Review
  9. Review
  10. Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Cláudia Righy ShinotsukaDepartment of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070, Belgium.
Alexandre BrasseurDepartment of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070, Belgium.
David FagnoulDepartment of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070, Belgium.
Timothy SoOptiscan Corporation, Hayward, CA, USA.
Jean-Louis VincentDepartment of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070, Belgium.
Jean-Charles PreiserDepartment of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070, Belgium. jean-charles.preiser@erasme.ulb.ac.be.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntravascular continuous glucose monitoring (CGM) may facilitate glycemic control in the intensive care unit (ICU). We compared the accuracy of a CGM device (OptiScanner®) with a standard reference method.

methodsAdult patients who had blood glucose (BG) levels >150 mg/dl and required insertion of an arterial and central venous catheter were included. The OptiScanner® was inserted into a multiple-lumen central venous catheter. Patients were treated using a dynamic-scale insulin algorithm to achieve BG values between 80 and 150 mg/dl. The BG values measured by the OptiScanner® were plotted against BG values measured using a reference analyzer. The correlation between the BG values measured using the two methods and the clinical relevance of any differences were assessed using the coefficient of determination (r

resultsThe analysis included 929 paired samples from 88 patients, monitored for a total of 2584 hours. Reference BG values ranged between 60 and 484 mg/dl. The r

conclusionsBased on the MARD, the performance of the OptiScanner® is adequate for use in ICU patients. Because recent standards for accuracy were not met, the OptiScanner® should not be used as a sole monitor. The assessment of glycemic variability is influenced by the time interval between BG determinations.

trial registrationClinicaltrials.gov NCT01720381 . Registered 31 October 2012.

Indexed as

AgedAutomationBlood GlucoseBlood Specimen CollectionCatheterization, Central VenousEquipment DesignFemaleGlycemic IndexHumansIntensive Care UnitsMaleMiddle AgedSpectrophotometry, InfraredBlood Glucose

Identifiers

PMID27884157
PMCPMC5123350

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.