Evidence map›Paper›PMID 27882486›Full record

ArticleDocumenta ophthalmologica. Advances in ophthalmology2016

VEP analysis methods in children with optic nerve hypoplasia: relationship to visual acuity and optic disc diameter.

John P Kelly, James O Phillips, Avery H Weiss

Abstract read
PubMed Publisher
In one paragraph

Article in Documenta ophthalmologica. Advances in ophthalmology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

John P KellyDivision of Ophthalmology, OA.5.345, Roger H. Johnson Vision Lab, Seattle Children's Hospital, 4800 Sand Point Way NE, Seattle, WA, 98105, USA. john.kelly@seattlechildrens.org.
James O PhillipsDivision of Ophthalmology, OA.5.345, Roger H. Johnson Vision Lab, Seattle Children's Hospital, 4800 Sand Point Way NE, Seattle, WA, 98105, USA.
Avery H WeissDivision of Ophthalmology, OA.5.345, Roger H. Johnson Vision Lab, Seattle Children's Hospital, 4800 Sand Point Way NE, Seattle, WA, 98105, USA.
University of Washington · USSeattle Children's Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAssessing vision in young children with optic nerve hypoplasia (ONH) is challenging due to multi-directional infantile nystagmus, the range of optic nerve loss, and cognitive delay. This study examined visual evoked potential (VEP) responses and averaging techniques in children with ONH. The assumption is that EEG epochs with inconsistent temporal phase would be associated with nystagmus, signal reduction due to axon loss, and visual inattention.

methodsA retrospective chart review was performed on 44 children (average age 2.2 years; SD 1.9). Optic disc diameter was estimated by ophthalmoscopy. Visual function was measured under binocular viewing and then compared to the eye with the larger optic disc to exclude secondary amblyopia. Visual acuity was measured by Teller cards or by recognition optotypes, and both measures were converted into log minimum angle of resolution (logMAR). VEPs were recorded to onset/offset of horizontal gratings and to reversing checkerboards. Signal-to-noise ratios (SNRs) were estimated from phase consistency across epochs in the Fourier domain. VEPs were also averaged after (1) correction of epochs for phase shifts across a limited bandwidth, or (2) selection of only epochs showing phase consistency.

resultsOptic disc diameter, logMAR, VEP amplitudes, and VEP SNR were all significantly inter-correlated. Optic disc diameter correlated best with VEP SNR (Spearman rho = 0.82; p < 0.001). Age-corrected logMAR correlated with optic disc diameter and VEP SNR (Spearman rho = -0.695 and 0.70, respectively; p < 0.001). VEP latency poorly correlated with optic disc diameter or logMAR. Correction of phase shifts or selection of epochs based on phase consistency significantly increased VEP amplitude and SNR for children with optic disc diameters <1000 microns. Correction of phase inconsistency did not improve the correlation of VEP parameters with optic disc diameter or with logMAR.

conclusionsIn ONH, the size of the optic nerve is correlated with VEP SNR and logMAR. The results imply a direct relationship between the reduction in optic nerve axons and generalized reduction in visual function. Our calculation of VEP SNR provides objective assessment of optic nerve function that is independent of subjective scoring of VEP peaks.

Indexed as

AmblyopiaChild, PreschoolElectroencephalographyEvoked Potentials, VisualFemaleHumansInfantMaleNystagmus, PathologicOphthalmoscopyOptic DiskOptic NerveOptic Nerve DiseasesRetrospective StudiesSignal-To-Noise RatioVisual AcuityChildrenNystagmusOptic nerve hypoplasiaSignal-to-noise ratioVisual evoked potential

Identifiers

PMID27882486
OpenAlexW2552769673

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.