Evaluation of daily patient positioning for radiotherapy with a commercial 3D surface-imaging system (Catalyst™).

F Walter, P Freislederer, C Belka, C Heinz, M Söhn, F Roeder

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed
9.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 89 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Use of surface tracking recordings to identify pitfalls during surface-guided radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025
    Article
  6. Article
  7. Review
  8. [Development and evaluation of a positioning system for radiotherapy patient based on structured light surface imaging].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

F WalterDepartment of Radiation Oncology, University Hospital of LMU Munich, Marchioninistr 15, 81377, Munich, Germany. Franziska.Walter@med.uni-muenchen.de.ORCID http://orcid.org/0000-0001-7912-322X
P FreisledererDepartment of Radiation Oncology, University Hospital of LMU Munich, Marchioninistr 15, 81377, Munich, Germany.
C BelkaDepartment of Radiation Oncology, University Hospital of LMU Munich, Marchioninistr 15, 81377, Munich, Germany.
C HeinzDepartment of Radiation Oncology, University Hospital of LMU Munich, Marchioninistr 15, 81377, Munich, Germany.
M SöhnDepartment of Radiation Oncology, University Hospital of LMU Munich, Marchioninistr 15, 81377, Munich, Germany.
F RoederDepartment of Radiation Oncology, University Hospital of LMU Munich, Marchioninistr 15, 81377, Munich, Germany.
LMU Klinikum · DEGerman Cancer Research Center · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo report our initial clinical experience with the novel surface imaging system Catalyst™ (C-RAD AB, Sweden) in connection with an Elekta Synergy linear accelerator for daily patient positioning in patients undergoing radiation therapy.

methodsWe retrospectively analyzed the patient positioning of 154 fractions in 25 patients applied to thoracic, abdominal, and pelvic body regions. Patients were routinely positioned based on skin marks, shifted to the calculated isocenter position and treated after correction via cone beam CT which served as gold standard. Prior to CBCT an additional surface scan by the Catalyst™ system was performed and compared to a reference surface image cropped from the planning CT to obtain shift vectors for an optimal surface match. These shift vectors were subtracted from the vectors obtained by CBCT correction to assess the theoretical setup error that would have occurred if the patients had been positioned using solely the Catalyst™ system. The mean theoretical set up-error and its standard deviation were calculated for all measured fractions and the results were compared to patient positioning based on skin marks only.

resultsIntegration of the surface scan into the clinical workflow did not result in a significant time delay. Regarding the entire group, the mean setup error by using skin marks only was 0.0 ± 2.1 mm in lateral, -0.4 ± 2.4 mm in longitudinal, and 1.1 ± 2.6 mm vertical direction. The mean theoretical setup error that would have occurred using solely the Catalyst™ was -0.1 ± 2.1 mm laterally, -1.8 ± 5.4 mm longitudinally, and 1.4 ± 3.2 mm vertically. No significant difference was found in any direction. For thoracic targets the mean setup error based on the Catalyst™ was 0.6 ± 2.6 mm laterally, -5.0 ± 7.9 mm longitudinally, and 0.5 ± 3.2 mm vertically. For abdominal targets, the mean setup error was 0.3 ± 2.2 mm laterally, 2.6 ± 1.8 mm longitudinally, and 2.1 ± 5.5 mm vertically. For pelvic targets, the setup error was -0.9 ± 1.5 mm laterally, -1.7 ± 2.8 mm longitudinally, and 1.6 ± 2.2 mm vertically. A significant difference between Catalyst™ and skin mark based positioning was only observed in longitudinal direction of pelvic targets.

conclusionOptical surface scanning using Catalyst™ seems potentially useful for daily positioning at least to complement usual imaging modalities in most patients with acceptable accuracy, although a significant improvement compared to skin mark based positioning could not be derived from the evaluated data. However, this effect seemed to be rather caused by the unexpected high accuracy of skin mark based positioning than by inaccuracy using the Catalyst™. Further on, surface registration in longitudinal axis seemed less reliable especially in pelvic localization. Therefore further prospective evaluation based on strictly predefined protocols is needed to determine the optimal scanning approaches and parameters.

Indexed as

FemaleHumansImaging, Three-DimensionalMaleNeoplasmsPatient PositioningRadiosurgeryRadiotherapy Planning, Computer-AssistedRetrospective StudiesCatalystCone-beam computed tomographyOptical surface scanningPatient positioning

Identifiers

PMID27881158
PMCPMC5122202
OpenAlexW2555095678

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.