ArticleRadiation oncology (London, England)2016
Evaluation of daily patient positioning for radiotherapy with a commercial 3D surface-imaging system (Catalyst™).
Article in Radiation oncology (London, England), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
48 citing papers in PubMed, 89 citations in OpenAlex.
- Evaluation of the clinical validity of fixation accuracy using an open-face black mask in head stereotactic radiotherapy.Radiological physics and technology · 2026Article
- Accuracy of Patient Setup Using Surface Guided Radiotherapy (SGRT) for Abdominal Malignancies.Methods and protocols · 2025Article
- Real-time volumetric CBCT reconstruction using surface and X-ray imaging for image-guided radiotherapy.Medical image analysis · 2025Article
- Enhancing patient positioning precision: a comparative analysis of surface-guided radiation therapy systems.Radiological physics and technology · 2025Article
- Use of surface tracking recordings to identify pitfalls during surface-guided radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025Article
- Clinical technique: evaluation of detection accuracy in surface-guided radiation therapy using CT references from different treatment planning systems.Radiological physics and technology · 2025Article
- From CBCT to MR-Linac in Image-Guided Prostate Cancer Radiotherapy Towards Treatment Personalization.Current oncology (Toronto, Ont.) · 2025Review
- [Development and evaluation of a positioning system for radiotherapy patient based on structured light surface imaging].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025Article
- Analysis of intra-fractional surface motion during adaptive radiation therapy and relation of internal vs. external position for prostate cancer.Radiation oncology (London, England) · 2025Article
- Data-Driven Volumetric Computed Tomography Image Generation From Surface Structures Using a Patient-Specific Deep Leaning Model.International journal of radiation oncology, biology, physics · 2025Article
- Patient-Specific CBCT Synthesis for Real-time Tumor Tracking in Surface-guided Radiotherapy.ArXiv · 2024Article
- Sensitivity Response Analysis of Optical Surface Monitoring Systems Using the Fitzpatrick Scale: A Phantom Study.Advances in radiation oncology · 2024Article
- Surface guided radiotherapy practice in paediatric oncology: a survey on behalf of the SIOPE Radiation Oncology Working Group.The British journal of radiology · 2024Article
- Setup and intra-fractional motion measurements using surface scanning in head and neck cancer radiotherapy- A feasibility study.Physics and imaging in radiation oncology · 2024Article
- Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system.Radiological physics and technology · 2023Article
- Going from 3D/3D to 2D/3D registration for noncoplanar setup verification in intracranial single-isocenter multiple-target hypofractionated stereotactic radiotherapy: comparison between kilo-voltage/mega-voltage image pairs and noncoplanar cone-beam computed tomography.Quantitative imaging in medicine and surgery · 2023Article
- Surface-Guided Radiotherapy: Can We Move on from the Era of Three-Point Markers to the New Era of Thousands of Points?Bioengineering (Basel, Switzerland) · 2023Review
- Setup accuracy and margins for surface-guided radiotherapy (SGRT) of head, thorax, abdomen, and pelvic target volumes.Scientific reports · 2023Article
- Surface guidance compared with ultrasound-based monitoring and diaphragm position in cone-beam computed tomography during abdominal stereotactic radiotherapy in breath-hold.Physics and imaging in radiation oncology · 2023Article
- Dose coverage and breath-hold analysis of breast cancer patients treated with surface-guided radiotherapy.Radiation oncology (London, England) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo report our initial clinical experience with the novel surface imaging system Catalyst™ (C-RAD AB, Sweden) in connection with an Elekta Synergy linear accelerator for daily patient positioning in patients undergoing radiation therapy.
methodsWe retrospectively analyzed the patient positioning of 154 fractions in 25 patients applied to thoracic, abdominal, and pelvic body regions. Patients were routinely positioned based on skin marks, shifted to the calculated isocenter position and treated after correction via cone beam CT which served as gold standard. Prior to CBCT an additional surface scan by the Catalyst™ system was performed and compared to a reference surface image cropped from the planning CT to obtain shift vectors for an optimal surface match. These shift vectors were subtracted from the vectors obtained by CBCT correction to assess the theoretical setup error that would have occurred if the patients had been positioned using solely the Catalyst™ system. The mean theoretical set up-error and its standard deviation were calculated for all measured fractions and the results were compared to patient positioning based on skin marks only.
resultsIntegration of the surface scan into the clinical workflow did not result in a significant time delay. Regarding the entire group, the mean setup error by using skin marks only was 0.0 ± 2.1 mm in lateral, -0.4 ± 2.4 mm in longitudinal, and 1.1 ± 2.6 mm vertical direction. The mean theoretical setup error that would have occurred using solely the Catalyst™ was -0.1 ± 2.1 mm laterally, -1.8 ± 5.4 mm longitudinally, and 1.4 ± 3.2 mm vertically. No significant difference was found in any direction. For thoracic targets the mean setup error based on the Catalyst™ was 0.6 ± 2.6 mm laterally, -5.0 ± 7.9 mm longitudinally, and 0.5 ± 3.2 mm vertically. For abdominal targets, the mean setup error was 0.3 ± 2.2 mm laterally, 2.6 ± 1.8 mm longitudinally, and 2.1 ± 5.5 mm vertically. For pelvic targets, the setup error was -0.9 ± 1.5 mm laterally, -1.7 ± 2.8 mm longitudinally, and 1.6 ± 2.2 mm vertically. A significant difference between Catalyst™ and skin mark based positioning was only observed in longitudinal direction of pelvic targets.
conclusionOptical surface scanning using Catalyst™ seems potentially useful for daily positioning at least to complement usual imaging modalities in most patients with acceptable accuracy, although a significant improvement compared to skin mark based positioning could not be derived from the evaluated data. However, this effect seemed to be rather caused by the unexpected high accuracy of skin mark based positioning than by inaccuracy using the Catalyst™. Further on, surface registration in longitudinal axis seemed less reliable especially in pelvic localization. Therefore further prospective evaluation based on strictly predefined protocols is needed to determine the optimal scanning approaches and parameters.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.