Evidence map›Paper›PMID 27874052›Full record

ArticleScientific reports2016

Multifunctional single beam acoustic tweezer for non-invasive cell/organism manipulation and tissue imaging.

Kwok Ho Lam, Ying Li, Yang Li, Hae Gyun Lim, Qifa Zhou, Koping Kirk Shung

Abstract read
In one paragraph

Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed.

  1. Article
  2. Article
  3. Pressure estimation of ultra-high frequency ultrasound using gas vesicles.The Journal of the Acoustical Society of America · 2024
    Article
  4. Review
  5. Article
  6. Article
  7. Sonic snares: Trapping microorganisms for deeper insights into swimming behavior and ciliary dynamics.Proceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Manipulation and Mechanical Deformation of Leukemia Cells by High-Frequency Ultrasound Single Beam.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Development of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes.Technology and health care : official journal of the European Society for Engineering and Medicine · 2021
    Article
  19. Article
  20. Acoustic Microfluidics.Annual review of analytical chemistry (Palo Alto, Calif.) · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kwok Ho LamDepartment of Electrical Engineering, The Hong Kong Polytechnic University, Hong Kong.
Ying LiNIH Transducer Resource Center and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
Yang LiNIH Transducer Resource Center and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
Hae Gyun LimNIH Transducer Resource Center and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
Qifa ZhouNIH Transducer Resource Center and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
Koping Kirk ShungNIH Transducer Resource Center and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.

Funding

A Resource on Medical Ultrasonic Transducer TechnologyP41EB002182 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2003 to 2016
$13.3M
Acoustic Trapping of Small Biological ParticlesR01EB012058 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2010 to 2013
$2.3M
NIBIB NIH HHS P41 EB002182NIBIB NIH HHS R01 EB012058
6 · The paper itself

Abstract

Non-contact precise manipulation of single microparticles, cells, and organisms has attracted considerable interest in biophysics and biomedical engineering. Similar to optical tweezers, acoustic tweezers have been proposed to be capable of manipulating microparticles and even cells. Although there have been concerted efforts to develop tools for non-contact manipulation, no alternative to complex, unifunctional tweezer has yet been found. Here we report a simple, low-cost, multifunctional single beam acoustic tweezer (SBAT) that is capable of manipulating an individual micrometer scale non-spherical cell at Rayleigh regime and even a single millimeter scale organism at Mie regime, and imaging tissue as well. We experimentally demonstrate that the SBAT with an ultralow f-number (f# = focal length/aperture size) could manipulate an individual red blood cell and a single 1.6 mm-diameter fertilized Zebrafish egg, respectively. Besides, in vitro rat aorta images were collected successfully at dynamic foci in which the lumen and the outer surface of the aorta could be clearly seen. With the ultralow f-number, the SBAT offers the combination of large acoustic radiation force and narrow beam width, leading to strong trapping and high-resolution imaging capabilities. These attributes enable the feasibility of using a single acoustic device to perform non-invasive multi-functions simultaneously for biomedical and biophysical applications.

Indexed as

AcousticsOptical TweezersAnimalsBiomedical EngineeringBiophysical PhenomenaFemaleHumansMicromanipulationOvarySoundZebrafish

Identifiers

PMID27874052
PMCPMC5118718

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.