ReviewAnnals of intensive care2016
Prediction of fluid responsiveness: an update.
Review in Annals of intensive care, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 9 registered trials, which are not on this map. Cited by 232 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison Between the Effect of Target-controlled Infusion of Propofol and Sevoflurane as Maintenance of Anesthesia to Intraoperative Hemodynamic Profile of Renal Transplant Recipient
Extension of the Rapid Ultrasound for Shock and Hypotension to Evaluate Volume Responsiveness
Outcomes of Metabolic Resuscitation Using Ascorbic Acid, Thiamine, and Glucocorticoids in the Early Treatment of Sepsis.
Bedside Resources to Gauge Intravascular Volume Status in Hypovolemic Infants in the Operating Room
Dynamic Parameters in Evaluation of Fluid Resposiveness in Cardiac Surgery Patients in the Early Postoperative Period
Association of Respiratory Variation of Superior Vena Cava in Transthoracic View and Fluid Responsiveness in Critically Ill Patients
Assessment of the Hemodynamic Effects of PEEP According to Alveolar Recruitment During the ARDS
Comparing The Ratio Of Femoral Vein Diameter To Femoral Artery Diameter With Pulse Pressure Variation As A Diagnostic Tool For Fluid Responsiveness In Mechanically Ventilated Patients; A Prospective Observational Study
Physician Knowledge Level of Intravenous Fluid Therapy in Hospitals: A Cross-Sectional Study
Who cites it
232 citing papers in PubMed, 5 syntheses or guidelines pooled it.
- Utilization of left ventricular outflow tract velocity time integral in the assessment of fluid responsiveness in adult patients with sepsis or septic shock - a systematic review.Journal of ultrasound · 2025Pooled it
- The association between integrating echocardiography use in the management of septic shock patients and outcomes in the intensive care unit: a systematic review and meta-analysis.Journal of ultrasound · 2025Pooled it
- Fluid challenge in critically ill patients receiving haemodynamic monitoring: a systematic review and comparison of two decades.Critical care (London, England) · 2022Pooled it
- Assessing Fluid Resuscitation in Adults with Sepsis Who Are Not Mechanically Ventilated: a Systematic Review of Diagnostic Test Accuracy Studies.Journal of general internal medicine · 2019Pooled it
- Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.BMC anesthesiology · 2018Pooled it
- Evaluation of the effects of Plasma-Lyte 148 or 0.9% saline on acid-base balance in patients undergoing neurosurgery: a randomized clinical trial.Einstein (Sao Paulo, Brazil) · 2026Trial
- Implications of Continuous Noninvasive Finger Cuff Arterial Pressure Device Use during Cesarean Delivery for Goal-Directed Fluid Therapy Preload Optimization: A Randomized Controlled Trial.BioMed research international · 2021Trial
- Trial
- Integrated haemodynamic monitoring of fluid responsiveness and fluid tolerance in critical care: from physiology to bedside applications.Journal of clinical monitoring and computing · 2026Review
- Detecting if change in end-tidal carbon dioxide signifies change in cardiac output for the prediction of fluid responsiveness in patients undergoing major abdominal oncosurgery: An observational study.Indian journal of anaesthesia · 2026Article
- Indian Society of Critical Care Medicine Position Statement on the Management of Paraquat Poisoning.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2026Article
- Peri-operative goal-directed haemodynamic therapy and high-risk patients: what's going on? A narrative review.Journal of anesthesia, analgesia and critical care · 2026Review
- Twenty-five years of septic shock hemodynamic resuscitation trials: a conceptual perspective.Critical care (London, England) · 2026Review
- Pulse Index Continuous Cardiac Output-Guided Hemodynamic Therapy in Living Donor Kidney Transplantation: A Prospective Cohort Study.Journal of clinical medicine research · 2026Article
- Central Venous Pressure Revisited: Physiology, Pitfalls, Misconceptions, and Modern Clinical Interpretation in Critical Care.Journal of clinical medicine · 2026Review
- Article
- Validation of the inferior vena cava collapsibility as a predictive marker of fluid responsiveness in spontaneously breathing patients.Scientific reports · 2026Article
- Article
- Real-time, artificial intelligence-guided intraoperative resuscitation and fluid management in trauma anesthesia.Current opinion in anaesthesiology · 2026Review
- Fluid management methods for severely burned patients: a narrative review.Journal of clinical monitoring and computing · 2026Review
172 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In patients with acute circulatory failure, the decision to give fluids or not should not be taken lightly. The risk of overzealous fluid administration has been clearly established. Moreover, volume expansion does not always increase cardiac output as one expects. Thus, after the very initial phase and/or if fluid losses are not obvious, predicting fluid responsiveness should be the first step of fluid strategy. For this purpose, the central venous pressure as well as other "static" markers of preload has been used for decades, but they are not reliable. Robust evidence suggests that this traditional use should be abandoned. Over the last 15 years, a number of dynamic tests have been developed. These tests are based on the principle of inducing short-term changes in cardiac preload, using heart-lung interactions, the passive leg raise or by the infusion of small volumes of fluid, and to observe the resulting effect on cardiac output. Pulse pressure and stroke volume variations were first developed, but they are reliable only under strict conditions. The variations in vena caval diameters share many limitations of pulse pressure variations. The passive leg-raising test is now supported by solid evidence and is more frequently used. More recently, the end-expiratory occlusion test has been described, which is easily performed in ventilated patients. Unlike the traditional fluid challenge, these dynamic tests do not lead to fluid overload. The dynamic tests are complementary, and clinicians should choose between them based on the status of the patient and the cardiac output monitoring technique. Several methods and tests are currently available to identify preload responsiveness. All have some limitations, but they are frequently complementary. Along with elements indicating the risk of fluid administration, they should help clinicians to take the decision to administer fluids or not in a reasoned way.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.