Evidence map›Paper›PMID 27853493›Full record

ArticleIranian journal of radiology : a quarterly journal published by the Iranian Radiological Society2016

Implantability, Complications, and Follow-Up After Transjugular Intrahepatic Portosystemic Stent-Shunt Creation With the 6F Self-Expanding Sinus-SuperFlex-Visual Stent.

Daniel Spira, Jakub Wiskirchen, Ulrich Lauer, Dominik Ketelsen, Konstantin Nikolaou, Benjamin Wiesinger

Open access · diamondAbstract read
In one paragraph

Article in Iranian journal of radiology : a quarterly journal published by the Iranian Radiological Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Daniel SpiraDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Jakub WiskirchenDepartment of Radiology and Nuclear Medicine, Franziskus Hospital, Bielefeld, Germany.
Ulrich LauerDepartment of Gastroenterology and Hepatology, Eberhard-Karls-University, Tubingen, Germany.
Dominik KetelsenDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tubingen, Germany.
Konstantin NikolaouDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tubingen, Germany.
Benjamin WiesingerDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tubingen, Germany.
University of Tübingen · DESt. Franziskus Hospital · DEUniversity Hospital Heidelberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe transjugular intrahepatic portosystemic stent-shunt (TIPSS) builds a shortcut between the portal vein and a liver vein, and represents a sophisticated alternative to open surgery in the management of portal hypertension or its complications.

objectivesTo describe clinical experiences with a low-profile nitinol stent system in TIPSS creation, and to assess primary and long-term success. PATIENTS AND

methodsTwenty-six patients (5 females, 21 males; mean age 54.6 years) were treated using a low-profile 6F self-expanding sinus-SuperFlex-Visual stent system. The indication for TIPSS creation was refractory bleeding in 9 of the 26 patients, refractory ascites in 18 patients, and acute thrombosis of the portal vein confluence in one patient. Portosystemic pressure gradients before and after TIPSS, periprocedural and long-term complications, and the time to orthotopic liver transplantation (OLT) or death were recorded.

resultsThe portosystemic pressure gradient was significantly reduced, from 20.9 ± 6.3 mmHg before to 8.2 ± 2.3 mmHg after TIPSS creation (P < 0.001). Procedure-related complications included acute tract occlusion (n = 2), liver hematoma (n = 1), hepatic encephalopathy (n = 1), and cardiac failure (n = 1). Three of the 26 patients had late-onset TIPSS occlusion (at 12, 12, and 39 months after TIPSS creation). Three patients died within one week after the procedure due to their poor general condition (multiorgan failure, acute respiratory distress syndrome, necrotizing pancreatitis, and aspiration pneumonia). Another four patients succumbed to their underlying advanced liver disease within one year after TIPSS insertion. Seven patients underwent OLT at a mean time of 9.4 months after TIPSS creation.

conclusionThe sinus-SuperFlex-Visual stent system can be safely deployed as a TIPSS device. The pressure gradient reduction was clinically sufficient to treat the patients' symptoms, and periprocedural complications were due to the TIPSS procedure per se rather than to the particular stent system employed in this study.

Indexed as

Low-Profile Stent SystemSelf-Expandable StentTIPSS

Identifiers

PMID27853493
PMCPMC5106871
OpenAlexW2344321125

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked