Evidence map›Paper›PMID 27845920›Full record

ArticlePhysics in medicine and biology2016

A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

Lulu Deng, Meaghan A O'Reilly, Ryan M Jones, Ran An, Kullervo Hynynen

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Dual-Mode 1-D Linear Ultrasound Array for Image-Guided Drug Delivery Enhancement Without Ultrasound Contrast Agents.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Review
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lulu DengPhysical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
Meaghan A O'ReillyPhysical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
Ryan M JonesPhysical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
Ran AnPhysical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
Kullervo HynynenPhysical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.

Funding

Ultrasound Therapy Delivery Through Intact SkullR01EB003268 · NIBIB · SUNNYBROOK & WOMEN'S COLL HLTH SCIS CTR · PI HYNYNEN, KULLERVO · 2003 to 2020
$8.2M
A Novel Ultrasound Phased Array and Sonication Method for Stroke TreatmentsR01EB009032 · NIBIB · SUNNYBROOK & WOMEN'S COLL HLTH SCIS CTR · PI HYNYNEN, KULLERVO · 2008 to 2012
$1.9M
NIBIB NIH HHS R01 EB003268NIBIB NIH HHS R01 EB009032
6 · The paper itself

Abstract

Focused ultrasound (FUS) phased arrays show promise for non-invasive brain therapy. However, the majority of them are limited to a single transmit/receive frequency and therefore lack the versatility to expose and monitor the treatment volume. Multi-frequency arrays could offer variable transmit focal sizes under a fixed aperture, and detect different spectral content on receive for imaging purposes. Here, a three-frequency (306, 612, and 1224 kHz) sparse hemispherical ultrasound phased array (31.8 cm aperture; 128 transducer modules) was constructed and evaluated for microbubble-mediated transcranial therapy and simultaneous cavitation mapping. The array is able to perform effective electronic beam steering over a volume spanning (-40, 40) and (-30, 50) mm in the lateral and axial directions, respectively. The focal size at the geometric center is approximately 0.9 (2.1) mm, 1.7 (3.9) mm, and 3.1 (6.5) mm in lateral (axial) pressure full width at half maximum (FWHM) at 1224, 612, and 306 kHz, respectively. The array was also found capable of dual-frequency excitation and simultaneous multi-foci sonication, which enables the future exploration of more complex exposure strategies. Passive acoustic mapping of dilute microbubble clouds demonstrated that the point spread function of the receive array has a lateral (axial) intensity FWHM between 0.8-3.5 mm (1.7-11.7 mm) over a volume spanning (-25, 25) mm in both the lateral and axial directions, depending on the transmit/receive frequency combination and the imaging location. The device enabled both half and second harmonic imaging through the intact skull, which may be useful for improving the contrast-to-tissue ratio or imaging resolution, respectively. Preliminary in vivo experiments demonstrated the system's ability to induce blood-brain barrier opening and simultaneously spatially map microbubble cavitation activity in a rat model. This work presents a tool to investigate optimal strategies for non-thermal FUS brain therapy and concurrent microbubble cavitation monitoring through the availability of multiple frequencies.

Indexed as

MicrobubblesAlgorithmsAnimalsImaging, Three-DimensionalMaleRatsRats, WistarSkullUltrasonic TherapyUltrasonography, Doppler, Transcranial

Identifiers

PMID27845920
PMCPMC5135599

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.