SynthesisThe Cochrane database of systematic reviews2016
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation.
Synthesis in The Cochrane database of systematic reviews, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 6 registered trials, which are not on this map. Cited by 135 papers, 10 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Videolaryngoscopy Versus Direct Laryngoscopy for Tracheal Intubation in Patients With Diabetes Mellitus
Can Videolaryngoscopy be the First Choice for Tracheal Intubation in Patients With Diabetes
Airway Injuries After Intubation Using Videolaryngoscopy Highly Curved Blades Versus Direct Laryngoscopy for Adult Patients Requiring Tracheal Intubation: a Randomized Controlled Trial
A Randomised Controlled Trial to Compare McGrath Videolaryngoscope Against Direct Laryngoscope for Endotracheal Intubation When Powered Air Purifying Respirator is Worn During the Current Coronavirus Disease 2019 Pandemic
A Randomized Comparison Between the C-MAC and Airtraq Videolaryngoscopes for First-attempt Intubation Success in Awake Patients With Anticipated Difficult Airway.
Comparison of EzVision® Videolaryngoscope and Gum Elastic Bougie-Assisted Machintosh Laryngoscopy in Patients Considering Difficult Intubation
Who cites it
135 citing papers in PubMed, 10 syntheses or guidelines pooled it, 370 citations in OpenAlex.
- Efficacy of video laryngoscopy versus direct laryngoscopy for critically Ill adults undergoing tracheal intubation: a trial sequential analysis and meta-analysis.BMC anesthesiology · 2026Pooled it
- Prevalence of Interventions After Difficult Airway Response Team Activation: A Systematic Review and Meta-Analysis.Respiratory care · 2025Pooled it
- Preventing unrecognised oesophageal intubation: a consensus guideline from the Project for Universal Management of Airways and international airway societies.Anaesthesia · 2022Guideline
- Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation: a Cochrane systematic review and meta-analysis update.British journal of anaesthesia · 2022Pooled it
- Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation.The Cochrane database of systematic reviews · 2022Pooled it
- Pooled it
- Surviving Sepsis Campaign: guidelines on the management of critically ill adults with Coronavirus Disease 2019 (COVID-19).Intensive care medicine · 2020Guideline
- Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults.Anaesthesia · 2020Guideline
- Video Versus Direct Laryngoscopy for Inpatient Emergency Intubation in Adults.Deutsches Arzteblatt international · 2018Pooled it
- Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation.The Cochrane database of systematic reviews · 2016Pooled it
- Video laryngoscopy as a teaching tool in direct intubation in undergraduate medical education - a randomized controlled trial.BMC medical education · 2026Trial
- Conventional versus video-assisted laryngoscopy for perioperative endotracheal intubation (COVALENT) - a randomized, controlled multicenter trial.BMC anesthesiology · 2023Trial
- Intubation using VieScope vs. Video laryngoscopy in full personal protective equipment - a randomized, controlled simulation trial.BMC anesthesiology · 2021Trial
- Comparison of the novel VieScope with conventional and video laryngoscope in a difficult airway scenario - a randomized, controlled simulation trial.BMC emergency medicine · 2021Trial
- Impact of retrograde transillumination while securing the airway in obese patients undergoing bariatric surgery.Journal of clinical monitoring and computing · 2020Trial
- Trial
- Trial
- Comparing the McGrath Mac Video Laryngoscope and Direct Laryngoscopy for Prehospital Emergency Intubation in Air Rescue Patients: A Multicenter, Randomized, Controlled Trial.Critical care medicine · 2019Trial
- A randomized controlled comparison of non-channeled king vision, McGrath MAC video laryngoscope and Macintosh direct laryngoscope for nasotracheal intubation in patients with predicted difficult intubations.BMC anesthesiology · 2019Trial
- Intubation of non-difficult airways using video laryngoscope versus direct laryngoscope: a randomized, parallel-group study.BMC anesthesiology · 2019Trial
75 more citing papers are in PubMed but not listed here.
Corrections and comments
- Updated by
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSuccessful tracheal intubation during general anaesthesia traditionally requires a line of sight to the larynx attained by positioning the head and neck and using a laryngoscope to retract the tongue and soft tissues of the floor of the mouth. Difficulties with intubation commonly arise, and alternative laryngoscopes that use digital and/or fibreoptic technology have been designed to improve visibility when airway difficulty is predicted or encountered. Among these devices, a rigid videolaryngoscope (VLS) uses a blade to retract the soft tissues and transmits a lighted video image to a screen.
objectivesOur primary objective was to assess whether use of videolaryngoscopy for tracheal intubation in adults requiring general anaesthesia reduces risks of complications and failure compared with direct laryngoscopy. Our secondary aim was to assess the benefits and risks of these devices in selected population groups, such as adults with obesity and those with a known or predicted difficult airway. SEARCH
methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and Embase on 10 February 2015. Our search terms were relevant to the review question and were not limited by outcomes. We carried out clinical trials register searches and forward and backward citation tracking. We reran the search on 12 January 2016; we added potential new studies of interest from the 2016 search to a list of 'Studies awaiting classification', and we will incorporate these studies into the formal review during the review update. SELECTION CRITERIA: We considered all randomized controlled trials and quasi-randomized studies with adult patients undergoing laryngoscopy performed with a VLS or a Macintosh laryngoscope in a clinical, emergency or out-of-hospital setting. We included parallel and cross-over study designs. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial quality and extracted data, consulting a third review author to resolve disagreements. We used standard Cochrane methodological procedures, including assessment of risk of bias. MAIN
resultsWe included 64 studies identified during the 2015 search that enrolled 7044 adult participants and compared a VLS of one or more designs with a Macintosh laryngoscope. We identified 38 studies awaiting classification and seven ongoing studies. Of the 64 included studies, 61 included elective surgical patients, and three were conducted in an emergency setting. Among 48 studies that included participants without a predicted difficult airway, 15 used techniques to simulate a difficult airway. Seven recruited participants with a known or predicted difficult airway, and the remaining studies did not specify or included both predicted and not predicted difficult airways. Only two studies specifically recruited obese participants. It was not possible to blind the intubator to the device, and we noted a high level of inevitable heterogeneity, given the large number of studies.Statistically significantly fewer failed intubations were reported when a VLS was used (Mantel-Haenszel (M-H) odds ratio (OR), random-effects 0.35, 95% confidence Interval (CI) 0.19 to 0.65; 38 studies; 4127 participants), and fewer failed intubations occurred when a VLS was used in participants with an anticipated difficult airway (M-H OR, random-effects 0.28, 95% CI 0.15 to 0.55; six studies; 830 participants). We graded the quality of this evidence as moderate on the basis of the GRADE system. Failed intubations were fewer when a VLS was used in participants with a simulated difficult airway (M-H OR, random-effects 0.18, 95% CI 0.04 to 0.77; nine studies; 810 participants), but groups with no predicted difficult airway provided no significant results (M-H OR, random-effects 0.61, 95% CI 0.22 to 1.67; 19 studies; 1743 participants).Eight studies reported on hypoxia, and only three of these described any events; results showed no differences between devices for this outcome (M-H OR, random-effects 0.39, 95% CI 0.10 to 1.44; 1319 participants). Similarly, few studies reported on mortality, noting no differences between devices (M-H OR, fixed-effect 1.09, 95% CI 0.65 to 1.82; two studies; 663 participants), and only one study reporting on the occurrence of respiratory complications (78 participants); we graded these three outcomes as very low quality owing to lack of data. We found no statistically significant differences between devices in the proportion of successful first attempts (M-H OR, random-effects 1.27, 95% CI 0.77 to 2.09; 36 studies; 4731 participants) nor in those needing more than one attempt. We graded the quality of this evidence as moderate. Studies reported no statistically significant differences in the incidence of sore throat in the postanaesthesia care unit (PACU) (M-H OR, random-effects 1.00 (95% CI 0.73 to 1.38); 10 studies; 1548 participants) nor at 24 hours postoperatively (M-H OR random-effects 0.54, 95% CI 0.27 to 1.07; eight studies; 844 participants); we graded the quality of this evidence as moderate. Data combined to include studies of cross-over design revealed statistically significantly fewer laryngeal or airway traumas (M-H OR, random-effects 0.68, 95% CI 0.48 to 0.96; 29 studies; 3110 participants) and fewer incidences of postoperative hoarseness (M-H OR, fixed-effect 0.57, 95% CI 0.36 to 0.88; six studies; 527 participants) when a VLS was used. A greater number of laryngoscopies performed with a VLS achieved a view of most of the glottis (M-H OR, random-effects 6.77, 95% CI 4.17 to 10.98; 22 studies; 2240 participants), fewer laryngoscopies performed with a VLS achieved no view of the glottis (M-H OR, random-effects 0.18, 95% CI 0.13 to 0.27; 22 studies; 2240 participants) and the VLS was easier to use (M-H OR, random-effects 7.13, 95% CI 3.12 to 16.31; seven studies; 568 participants).Although a large number of studies reported time required for tracheal intubation (55 studies; 6249 participants), we did not present an effects estimate for this outcome owing to the extremely high level of statistical heterogeneity (I AUTHORS'
conclusionsVideolaryngoscopes may reduce the number of failed intubations, particularly among patients presenting with a difficult airway. They improve the glottic view and may reduce laryngeal/airway trauma. Currently, no evidence indicates that use of a VLS reduces the number of intubation attempts or the incidence of hypoxia or respiratory complications, and no evidence indicates that use of a VLS affects time required for intubation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.