Evidence map›Paper›PMID 27844231›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2017

A new method to precisely control the depth of percutaneous screws into the pedicle by counting the rotation number of the screw with low radiation exposure: technical note.

Xu Li, Feng Zhang, Wenzhi Zhang, Xifu Shang, Jintao Han, Pengfei Liu

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. The Michel Benoist and Robert Mulholland yearly European Spine Journal Review: a survey of the "surgical and research" articles in the European Spine Journal, 2017.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2018
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Xu LiDepartment of Orthopedics, Spine Center, Anhui Medical University Affiliated Provincial Hospital, No. 17, Lujiang Road, Hefei, 230041, China.
Feng ZhangDepartment of Orthopedics, Spine Center, Anhui Medical University Affiliated Provincial Hospital, No. 17, Lujiang Road, Hefei, 230041, China.
Wenzhi ZhangDepartment of Orthopedics, Spine Center, Anhui Medical University Affiliated Provincial Hospital, No. 17, Lujiang Road, Hefei, 230041, China. zwzspine@hotmail.com.
Xifu ShangDepartment of Orthopedics, Spine Center, Anhui Medical University Affiliated Provincial Hospital, No. 17, Lujiang Road, Hefei, 230041, China.
Jintao HanPeking University Third Hospital Intervention and Vascular Surgery, Beijing, 100083, China.
Pengfei LiuDepartment of Orthopedics, Spine Center, Anhui Medical University Affiliated Provincial Hospital, No. 17, Lujiang Road, Hefei, 230041, China.
Anhui Medical University · CNPeking University Third Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designTechnique note.

objectivesTo report a new method for precisely controlling the depth of percutaneous pedicle screws (PPS)-without radiation exposure to surgeons and less fluoroscopy exposure to patients than with conventional methods. PPS is widely used in minimal invasive spine surgery; the advantages include reduced muscle damage, pain, and hospital stays. However, placement of PPS demands repeated checking with fluoroscopy. Thus, radiation exposure is considerable for both surgeons and patients.

methodsThe PPS depth was determined by counting rotations of the screws. The distance between screw threads can be measured for particular screws; thus, full rotations of the PPS results in the screw advancing in the pedicle the distance between screw threads. To fully insert screws into the pedicle, the number of full rotations is equal to the number of threads in the PPS.

resultsWe applied this technique in 58 patients with thoracolumbar fracture. The position and depth of the screws was checked during the operation with the C-arm and after operation by anteroposterior X-ray film or computed tomography. No additional procedures were required to correct the screws; we observed no neurological deficits or malpositioning of the screws. In the screw placement procedure, the radiation exposure for surgeons is zero, and the patient is well protected from extensive radiation exposure.

conclusionsThis method of counting rotation of screws is a safe way to precisely determine the depth of PPS in the placement procedure. LEVEL OF EVIDENCE: IV.

Indexed as

FluoroscopyPedicle ScrewsFemaleFracture FixationHumansLumbar VertebraeMaleMiddle AgedOccupational ExposureRadiation ExposureRotationSpinal FracturesThoracic VertebraeDepth of the screwsPercutaneous pedicle screws (PPS)Radiation exposureRadiation protection

Identifiers

PMID27844231
OpenAlexW2552507150

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.