Trial reportClinical orthopaedics and related research2017
High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures.
Trial report in Clinical orthopaedics and related research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
44 citing papers in PubMed, 2 syntheses or guidelines pooled it, 75 citations in OpenAlex.
- Dual-plating is associated with lower implant removal rates compared with single-plate fixation for midshaft clavicle fractures: a meta-analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Pooled it
- Pooled it
- Does implant removal of superior clavicle plate osteosynthesis affect the functional outcome: a prospective trial.Archives of orthopaedic and trauma surgery · 2022Trial
- Practice patterns in indications, timing, and imaging for clavicle hardware removal: a survey among German-speaking shoulder surgeons.BMC musculoskeletal disorders · 2026Article
- Review
- Low-profile 2.7 mm VA-LCP plates vs. 3.5 mm LCP plates for midshaft clavicle osteosynthesis: a retrospective comparison.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Article
- Have New Plate Designs Reduced the Rate of Hardware Removal Following Midshaft Clavicle Fracture Fixation?Journal of clinical medicine · 2025Article
- Implant irritation and removal rates in operatively treated multiple rib fractures: a 49-month follow-up study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025Observational
- A new method to predict refracture risk after locking compression plate removal of clavicle shaft.BMC surgery · 2025Article
- Usefulness of using pure β-TCP bone substitute (Neobone) in post-orthopedic implant removal procedures.PloS one · 2025Article
- [Surgical access route and choice of implant in the region of the clavicle shaft].Unfallchirurgie (Heidelberg, Germany) · 2024Review
- Do postoperative outcomes vary between midshaft clavicle fractures of 2, 3, or more than 3 fragments?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
- Functional outcomes and complications of plate fixation for midshaft clavicle fractures by type and location: a systematic review and meta-analysis.JSES international · 2024Review
- The use of precontoured plates for midshaft clavicle fractures is not always the best course of treatment.Anatomy & cell biology · 2023Article
- Two-staged management of ankle fracture-dislocations with a posterior fragment: computer-tomography-based classification, treatment and its outcome.Archives of orthopaedic and trauma surgery · 2023Article
- Indications for the removal of implants after fracture healing: A comparison between human and veterinary medicine.Veterinarni medicina · 2023Review
- Refracture after plate removal of midshaft clavicle fractures after bone union-incidence, risk factors, management and outcomes.BMC musculoskeletal disorders · 2023Article
- Non-operative vs. operative treatment for multiple rib fractures after blunt thoracic trauma: a multicenter prospective cohort study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2023Observational
- Proximal humeral fracture-dislocation: Outcome analysis in osteosynthesis and arthroplasties.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023Article
Corrections and comments
- Commented on byCORR Insights2017
Authors and funding
8 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundStudies comparing plate with intramedullary nail fixation of displaced midshaft clavicle fractures show faster recovery in the plate group and implant-related complications in both groups after short-term followup (6 or 12 months). Knowledge of disability, complications, and removal rates beyond the first postoperative year will help surgeons in making a decision regarding optimal implant choice. However, comparative studies with followup beyond the first year or two are scarce. QUESTIONS/PURPOSES: We asked: (1) Does plate fixation or intramedullary nail fixation for displaced midshaft clavicle fractures result in less disability? (2) Which type of fixation, plate or intramedullary, is more frequently associated with implant-related irritation and implant removal? (3) Is plate or intramedullary fixation associated with postoperative complications beyond the first postoperative year?
methodsBetween January 2011 and August 2012, patients with displaced midshaft clavicle fractures were enrolled and randomized to plate or intramedullary nail fixation. A total of 58 patients with plate and 62 patients with intramedullary nails initially were enrolled. Minimum followup was 30 months (mean, 39 months; range, 30-51 months). Two patients (3%) with plate fixation and two patients (3%) with intramedullary nails were lost to followup. The QuickDASH was obtained at final followup and compared between patients who had plate fixation and those who had intramedullary nail fixation. Postoperative complications measured include infection, implant-related irritation, implant failure, nonunion, and refracture after implant removal. Indications for implant removal included implant-related irritation, implant failure, nonunion, patient's wish, or surgeon's preference.
resultsBetween patients with plate versus intramedullary nail fixation, there were no differences in QuickDASH scores (plate, 1.8 ± 3.6; intramedullary nail, 1.8 ± 7.2; mean difference, -0.7; 95% CI, -2.2 to 2.04; p = 0.95). The proportion of patients having implant-related irritation was not different (39 of 56 [70%] versus 41 of 62 [66%]; relative risk, 1.05; 95% CI, 0.82-1.35; p = 0.683). Intramedullary fixation was associated with a higher likelihood of implant removal (51 of 62 [82%] versus 28 of 56 [50%]; relative risk, 1.65; 95% CI, 1.24-2.19; p < 0.001). Among the removed implants more plates than intramedullary nails were removed after the 1-year followup (12 of 28 [43%] versus six of 51 [12%]; p = 0.002). There were no infections, implant breakage, nonunions, or refractures between the 1-year and final followup in either group.
conclusionsAfter a mean followup of 39 months, disability scores were excellent. Major complications did not occur after the 1-year followup. A frequent and bothersome problem after both surgical treatments is implant-related irritation, resulting in high rates of implant removal, after 1 year. Future research could focus on analyzing risk factors for implant irritation or removal. LEVEL OF EVIDENCE: Level II, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.