ArticleHeart and vessels2017

Optical coherence tomography: influence of contrast concentration on image quality and diagnostic confidence.

Florian Blachutzik, Stephan Achenbach, Holger Nef, Christian Hamm, Oliver Dörr, Niklas Boeder, Mohamed Marwan, Monique Tröbs, Reinhard Schneider, Jens Röther and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Florian BlachutzikDepartment of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany. florian.blachutzik@uk-erlangen.de.ORCID http://orcid.org/0000-0002-7695-3663
Stephan AchenbachDepartment of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
Holger NefDepartment of Cardiology, University Hospital Giessen, Giessen, Germany.
Christian HammDepartment of Cardiology, University Hospital Giessen, Giessen, Germany.
Oliver DörrDepartment of Cardiology, University Hospital Giessen, Giessen, Germany.
Niklas BoederDepartment of Cardiology, University Hospital Giessen, Giessen, Germany.
Mohamed MarwanDepartment of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
Monique TröbsDepartment of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
Reinhard SchneiderDepartment of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
Jens RötherDepartment of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
Christian SchlundtDepartment of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

OCT requires intracoronary injection of contrast agent to remove blood from the coronary lumen during data acquisition, which is a possible limitation of this method. Aim of this study was to analyze the influence of iodine concentration on image quality and diagnostic certainty of optical coherence tomography (OCT). OCT sequences acquired using contrast agent with a reduced concentration of 150 mg iodine/ml and a standard concentration of 350 mg iodine/ml were analyzed. Cross-sectional images with a spacing of 10 mm were evaluated regarding image quality and diagnostic confidence. A total of 67 OCT sequences acquired in 24 patients were analyzed. 31 sequences were acquired using contrast agent with a concentration of 150 mg iodine/ml and 36 sequences with a concentration of 350 mg iodine/ml. The percentage of remaining blood streaks in the cross sections was significantly lower for 350 mg iodine/ml compared to 150 mg iodine/ml (19 ± 21 vs. 34 ± 26%, p = 0.013). Contrast with 350 mg iodine/ml showed a significantly higher percentage of completely flushed pullback length as compared to 150 mg iodine/ml (78 ± 24 vs. 58 ± 27%, p = 0.004). Diagnostic certainty was significantly higher for 350 mg iodine/ml than for 150 mg iodine/ml (Likert scale average 1.4 ± 0.7 vs. 2.1 ± 1.2, p < 0.001; Likert scale: 1 = absolutely confident, 2 = confident with slight doubts, 3 = doubtful/not confident, 4 = non-diagnostic). Regarding image quality and diagnostic certainty, contrast agent with a concentration of 350 mg iodine/ml is superior to 150 mg iodine/ml.

Indexed as

Tomography, Optical CoherenceAgedContrast MediaCoronary AngiographyCoronary Artery DiseaseCross-Sectional StudiesFemaleGermanyHumansImage Interpretation, Computer-AssistedIodineMaleMiddle AgedPercutaneous Coronary InterventionContrast MediaIodineCoronary angiographyOptical coherence tomographyPercutaneous coronary intervention