ArticleLasers in medical science2017
Experimental research on laser interference micro/nano fabrication of hydrophobic modification of stent surface.
Article in Lasers in medical science, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Surface engineering and the application of laser-based processes to stents - A review of the latest development.Bioactive materials · 2022Review
- Microstructure control of the wettability and adhesion of Al alloy surfaces.RSC advances · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Coronary artery disease (CAD) has become one of the important causes of human death, and coronary stent implantation is one of the most effective methods for the treatment of CAD. But the current clinical treatment has a high long-term restenosis rate and is easy to form late stent thrombosis. In order to solve these problems, coronary artery stent surface was directly modified by laser interference lithography and the highly ordered concave structures were fabricated. The morphology and contact angle (CA) of the microstructure were measured with scanning electron microscopy (SEM) and CA system. The water repellent property of the stent was also evaluated by the method of contacting the water drop with the stent and then separating. The result showed that the close-packed concave structure with the period of about 12.194 μm can be fabricated on the stent surface under special parameters (laser energy density of 3.5 J/cm
Indexed as
Identifiers
27826674What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.