Evidence map›Paper›PMID 27822851›Full record

Trial reportPharmaceutical research2017

SPECT-CT Comparison of Lung Deposition using a System combining a Vibrating-mesh Nebulizer with a Valved Holding Chamber and a Conventional Jet Nebulizer: a Randomized Cross-over Study.

Jonathan Dugernier, Michel Hesse, Rita Vanbever, Virginie Depoortere, Jean Roeseler, Jean-Bernard Michotte, Pierre-François Laterre, François Jamar, Gregory Reychler

Registry-linked trialAbstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Pharmaceutical research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03597334 (Aerosol Therapy in Intensive Care Units), which is not on this map. Cited by 40 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
40citing papers in PubMed, 2 pooled it
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03597334 completednot on this mapstarted 2018, after this paper: background citation

Aerosol Therapy in Intensive Care Units: a Prospective Observation Study

Typeobservational_patient_registrySponsorlvshanRan2018 to 2018Enrolled1,095ConditionsRespiration, Artificial, Critical CareArmsaerosol therapy
3 · Its place in the literature

Who cites it

40 citing papers in PubMed, 2 syntheses or guidelines pooled it, 71 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Trial
  5. Article
  6. Review
  7. Article
  8. Article
  9. Short-acting βInternal medicine (Tokyo, Japan) · 2025
    Article
  10. Article
  11. Article
  12. Review
  13. Nebuliser therapy in critical care: The past, present and future.Journal of the Intensive Care Society · 2024
    Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
  19. Nebulized mRNA-Encoded Antibodies Protect Hamsters from SARS-CoV-2 Infection.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Jonathan DugernierInstitut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium. Jonathan.dugernier@uclouvain.be.
Michel HesseMédecine Nucléaire, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
Rita VanbeverLouvain Drug Research Institute (LDRI), Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels, Belgium.
Virginie DepoortereMédecine Nucléaire, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
Jean RoeselerSoins Intensifs, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
Jean-Bernard MichotteHaute Ecole de Santé Vaud, Filière physiothérapie, University of Applied Sciences and Arts Western Switzerland, Avenue de Beaumont 21, 1011, Lausanne, Switzerland.
Pierre-François LaterreSoins Intensifs, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
François JamarMédecine Nucléaire, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
Gregory ReychlerInstitut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
Cliniques Universitaires Saint-Luc · BEHES-SO University of Applied Sciences and Arts Western Switzerland · CHUCLouvain · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare in vivo the total and regional pulmonary deposition of aerosol particles generated by a new system combining a vibrating-mesh nebulizer with a specific valved holding chamber and constant-output jet nebulizer connected to a corrugated tube.

methodsCross-over study comparing aerosol delivery to the lungs using two nebulizers in 6 healthy male subjects: a vibrating-mesh nebulizer combined with a valved holding chamber (Aerogen Ultra®, Aerogen Ltd., Galway, Ireland) and a jet nebulizer connected to a corrugated tube (Opti-Mist Plus Nebulizer®, ConvaTec, Bridgewater, NJ). Nebulizers were filled with diethylenetriaminepentaacetic acid labelled with technetium-99 m (

resultsPulmonary aerosol deposition from SPECT-CT analysis was six times increased with the vibrating-mesh nebulizer as compared to the jet nebulizer (34.1 ± 6.0% versus 5.2 ± 1.1%, p < 0.001). However, aerosol penetration expressed as the three-dimensional normalized ratio of the outer and the inner regions of the lungs was similar between both nebulizers.

conclusionsThis study demonstrated the high superiority of the new system combining a vibrating-mesh nebulizer with a valved holding chamber to deliver nebulized particles into the lungs as comparted to a constant-output jet nebulizer with a corrugated tube.

Indexed as

Administration, InhalationAdultAerosolsCross-Over StudiesDrug Delivery SystemsEquipment DesignHealthy VolunteersHumansInhalation SpacersLungMaleNebulizers and VaporizersParticle SizeProstheses and ImplantsTechnetiumTechnetium Tc 99m PentetateAerosolsTechnetiumTechnetium-99Technetium Tc 99m PentetateAerosol deliveryHealthy subjectsSingle photon emission computed tomographySpacerVibrating-mesh nebulizer

Identifiers

PMID27822851
OpenAlexW2551306921

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.