SynthesisThe Cochrane database of systematic reviews2016
Integrated versus non-integrated orbital implants for treating anophthalmic sockets.
Synthesis in The Cochrane database of systematic reviews, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.
- Integrated versus non-integrated orbital implants for treating anophthalmic sockets.The Cochrane database of systematic reviews · 2016Pooled it
- Anophthalmic Sockets: A Retrospective Review of Enucleations, Eviscerations, and Exenterations Performed and Managed in a Tertiary Care Hospital.Journal of clinical medicine · 2025Article
- Digital smartphone versus analogue methods of measuring orbital implant motility after enucleation.Eye (London, England) · 2025Observational
- Assessment of intraorbital hydroxyapatite implant exposure beyond 10 years of implantation.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025Article
- Article
- Orbital Complications and Cost Analysis of Enucleation by Myoconjunctival versus Conventional Techniques for Retinoblastoma.Ocular oncology and pathology · 2023Article
- Assessing the results of anophthalmic prostheses.Indian journal of ophthalmology · 2021Observational
- Anophthalmic Socket Syndrome: Prevalence, Impact and Management Strategies.Clinical ophthalmology (Auckland, N.Z.) · 2021Review
- Article
- Prosthetic Reconstruction of Orbital Defects.Seminars in plastic surgery · 2019Review
- Ab interno evisceration.International journal of ophthalmology · 2019Article
- Single-Stage Orbital Socket Reconstruction Using the Oversized Dermis Fat Graft and the 22 mm Silicone Orbital Implant after an Extended Enucleation.Case reports in ophthalmological medicine · 2018Article
- Osseointegrated Implants and Prosthetic Reconstruction Following Skull Base Surgery.Seminars in plastic surgery · 2017Review
- An innovative proposal for anophthalmic cavity reconstruction surgery with bone cement: a case report.Arquivos brasileiros de oftalmologiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAnophthalmia is the absence of one or both eyes, and it can be congenital (i.e. a birth defect) or acquired later in life. There are two main types of orbital implant: integrated, whereby the implant receives a blood supply from the body that allows for the integration of the prosthesis within the tissue; and non-integrated, where the implant remains separate. Despite the remarkable progress in anophthalmic socket reconstruction and in the development of various types of implants, there are still uncertainties about the real roles of integrated (hydroxyapatite (HA), porous polyethylene (PP), composites) and non-integrated (polymethylmethacrylate (PMMA)/acrylic and silicone) orbital implants in anophthalmic socket treatment.
objectivesTo assess the effects of integrated versus non-integrated orbital implants for treating anophthalmic sockets. SEARCH
methodsWe searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2016), Embase (January 1980 to August 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to August 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 8 August 2016. SELECTION CRITERIA: Randomised controlled trials (RCTs) and quasi-RCTs of integrated and non-integrated orbital implants for treating anophthalmic sockets. DATA COLLECTION AND ANALYSIS: Two authors independently selected relevant trials, assessed methodological quality and extracted data. MAIN
resultsWe included three studies with a total of 284 participants (250 included in analysis). The studies were conducted in India, Iran and the Netherlands. The three studies were clinically heterogenous, comparing different materials and using different surgical techniques. None of the included studies used a peg (i.e. a fixing pin used to connect the implant to the prosthesis). In general the trials were poorly reported, and we judged them to be at unclear risk of bias.One trial compared HA using traditional enucleation versus alloplastic implantation using evisceration (N = 100). This trial was probably not masked. The second trial compared PP with scleral cap enucleation versus PMMA with either myoconjunctival or traditional enucleation (N = 150). Although participants were not masked, outcome assessors were. The last trial compared HA and acrylic using the enucleation technique (N = 34) but did not report comparative effectiveness data.In the trial comparing HA versus alloplastic implantation, there was no evidence of any difference between the two groups with respect to the proportion of successful procedures at one year (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.95 to 1.09, N = 100, low-certainty evidence). People receiving HA had slightly worse horizontal implant mobility compared to the alloplastic group (mean difference (MD) -3.35 mm, 95% CI -4.08 to -2.62, very low-certainty evidence) and slightly worse vertical implant motility (MD -2.76 mm, 95% CI -3.45 to -2.07, very low-certainty evidence). As different techniques were used - enucleation versus evisceration - it is not clear whether these differences in implant motility can be attributed solely to the type of material. Investigators did not report adverse events.In the trial comparing PP versus PMMA, there was no evidence of any difference between the two groups with respect to the proportion of successful procedures at one year (RR 0.92, 95% CI 0.84 to 1.01, N = 150, low-certainty evidence). There was very low-certainty evidence of a difference in horizontal implant motility depending on whether PP was compared to PMMA with traditional enucleation (MD 1.96 mm, 95% CI 1.01 to 2.91) or PMMA with myoconjunctival enucleation (-0.57 mm, 95% CI -1.63 to 0.49). Similarly, for vertical implant motility, there was very low-certainty evidence of a difference in the comparison of PP to PMMA traditional (MD 3.12 mm 95% CI 2.36 to 3.88) but no evidence of a difference when comparing PP to PMMA myoconjunctival (MD -0.20 mm 95% CI -1.28 to 0.88). Four people in the PP group (total N = 50) experienced adverse events (i.e. exposures) compared to 6/100 in the PMMA groups (RR 17.82, 95% CI 0.98 to 324.67, N = 150, very low-certainty evidence).None of the studies reported socket sphere size, cosmetic effect or quality of life measures. AUTHORS'
conclusionsCurrent very low-certainty evidence from three small published randomised controlled trials did not provide sufficient evidence to assess the effect of integrated and non-integrated material orbital implants for treating anophthalmic sockets. This review underlines the need to conduct further well-designed trials in this field.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.