Evidence map›Paper›PMID 27819747›Full record

SynthesisThe Cochrane database of systematic reviews2016

Infant position in neonates receiving mechanical ventilation.

May Rivas-Fernandez, Marta Roqué I Figuls, Ana Diez-Izquierdo, Joaquin Escribano, Albert Balaguer

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed, 4 pooled it
5.1field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 4 syntheses or guidelines pooled it, 122 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Prone position for acute respiratory failure in adults.The Cochrane database of systematic reviews · 2015
    Pooled it
  5. Trial
  6. Trial
  7. [Clinical study of prone positioning in invasive respiratory support for neonatal respiratory distress syndrome].Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics · 2024
    Trial
  8. Trial
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Review
  14. Observational
  15. Observational
  16. Article
  17. Article
  18. Article
  19. Article
  20. Early and consistent safe sleep practices in the neonatal intensive care unit: a sustained regional quality improvement initiative.Journal of perinatology : official journal of the California Perinatal Association · 2024
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

May Rivas-FernandezDepartment of Pediatrics, Hospital Universitari General de Catalunya, Sant Cugat del Valles, Barcelona, Spain, 08190.
Marta Roqué I Figuls
Ana Diez-Izquierdo
Joaquin Escribano
Albert Balaguer
Hospital General de Catalunya · ESIberoamerican Cochrane Centre · ESUniversidad Rovira i Virgili · ESUniversitat Internacional de Catalunya · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn patients of various ages undergoing mechanical ventilation (MV), it has been observed that positions other than the standard supine position, such as the prone position, may improve respiratory parameters. The benefits of these positions have not been clearly defined for critically ill newborns receiving MV.This is an update of a review first published in 2005 and last updated in 2013.

objectivesPrimary objectiveTo assess the effects of different positioning of newborn infants receiving MV (supine vs prone, lateral decubitus or quarter turn from prone) in improving short-term respiratory outcomes. Secondary objectiveTo assess the effects of different positioning of newborn infants receiving MV on mortality and neuromotor and developmental outcomes over the long term, and on other complications of prematurity. SEARCH

methodsWe used the standard search strategy of the Cochrane Neonatal Review Group to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 8), MEDLINE via PubMed (1966 to 22 August 2016), Embase (1980 to 22 August 2016) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL; 1982 to 22 August 2016). We also searched clinical trials databases, conference proceedings and reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. SELECTION CRITERIA: Randomised and quasi-randomised clinical trials comparing different positions in newborns receiving mechanical ventilation. DATA COLLECTION AND ANALYSIS: Three unblinded review authors independently assessed trials for inclusion in the review and extracted study data. We used standard methodological procedures as expected by The Cochrane Collaboration and assessed the quality of the evidence using the GRADE approach. If the meta-analysis was not appropriate owing to substantial clinical heterogeneity between trials, we presented review findings in narrative format. MAIN

resultsWe included in this review 19 trials involving 516 participants. Seven of the included studies (N = 222) had not been evaluated in the previous review. Investigators compared several positions: prone versus supine, prone alternant versus supine, prone versus lateral right, lateral right versus supine, lateral left versus supine, lateral alternant versus supine, lateral right versus lateral left, quarter turn from prone versus supine, quarter turn from prone versus prone and good lung dependent versus good lung uppermost.Apart from two studies that compared lateral alternant versus supine, one comparing lateral right versus supine and two comparing prone or prone alternant versus the supine position, all included studies had a cross-over design. In five studies, infants were ventilated with continuous positive airway pressure (CPAP); in the other studies, infants were treated with conventional ventilation (CV).Risks of bias did not differ substantially for different comparisons and outcomes. This update detects a moderate to high grade of inconsistency, similar to previous versions. However, for the analysed outcomes, the direction of effect was the same in all studies. Therefore, we consider that this inconsistency had little effect on the conclusions of the meta-analysis. When comparing prone versus supine position, we observed an increase in arterial oxygen tension (PO AUTHORS'

conclusionsThis update of our last review in 2013 supports previous conclusions. Evidence of low to moderate quality favours the prone position for slightly improved oxygenation in neonates undergoing mechanical ventilation. However, we found no evidence to suggest that particular body positions during mechanical ventilation of the neonate are effective in producing sustained and clinically relevant improvement.

Indexed as

HumansInfant, NewbornOxygenPatient PositioningProne PositionRandomized Controlled Trials as TopicRespiration, ArtificialSupine PositionOxygen

Identifiers

PMID27819747
PMCPMC6734119
OpenAlexW1868802531

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.