Cardiovascular magnetic resonance in patients with magnetic resonance conditional pacemaker systems at 1.5 T: influence of pacemaker related artifacts on image quality including first pass perfusion, aortic and mitral valve assessment, flow measurement, short tau inversion recovery and T1-weighted imaging.

Oliver Klein-Wiele, Marietta Garmer, Martin Busch, Serban Mateiescu, Rhyan Urbien, Gianluca Barbone, Kaffer Kara, Michael Schulte-Hermes, Frauke Metz, Birgit Hailer and 1 more

Abstract readReview
PubMed Publisher
In one paragraph

Review in The international journal of cardiovascular imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. SCMR expert consensus statement for cardiovascular magnetic resonance of patients with a cardiac implantable electronic device.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Guideline
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Feasibility of adenosine stress cardiovascular magnetic resonance perfusion imaging in patients with MR-conditional transvenous permanent pacemakers and defibrillators.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2022
    Article
  9. Safety and image quality of cardiovascular magnetic resonance imaging in patients with retained epicardial pacing wires after heart transplantation.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2021
    Article
  10. Review
  11. Cardiac MRI-Update 2020.Der Radiologe · 2020
    Review
  12. Artefacts in 1.5 Tesla and 3 Tesla cardiovascular magnetic resonance imaging in patients with leadless cardiac pacemakers.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2018
    Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Oliver Klein-WieleDepartment of Cardiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany. o.klein-wiele@kk-essen.de.
Marietta GarmerDepartment of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
Martin BuschDepartment of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
Serban MateiescuDepartment of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
Rhyan UrbienDepartment of Cardiology, Katholisches Klinikum Essen, University of Witten/Herdecke, Hülsmannstraße 17, 45355, Essen, Germany.
Gianluca BarboneDepartment of Cardiology, Katholisches Klinikum Essen, University of Witten/Herdecke, Hülsmannstraße 17, 45355, Essen, Germany.
Kaffer KaraCardiovascular Centre, Josef Hospital, University of Bochum, Gudrunstr. 56, 44791, Bochum, Germany.
Michael Schulte-HermesDepartment of Cardiology, Prosper-Hospital Recklinghausen, University of Witten/Herdecke, Mühlenstraße 27, 45659, Recklinghausen, Germany.
Frauke MetzDepartment of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
Birgit HailerDepartment of Cardiology, Katholisches Klinikum Essen, University of Witten/Herdecke, Hülsmannstraße 17, 45355, Essen, Germany.
Dietrich GrönemeyerDepartment of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

There are only limited data on the impact of device-related artifacts on image quality in cardiovascular magnetic resonance imaging (CMR) in patients with pacemakers (PM). Adenosine stress perfusion, T1-weighted imaging and flow measurement as well as valve characterization have not been evaluated previously concerning artifact burden. We aimed to assess image quality in all routinely used CMR sequences. We analyzed 2623 myocardial segments in CMR scans of 61 patients with MR conditional PM (mean age 72.1 ± 11.5 years), 23 (37.7%) with right sided, 38 (62.3%) with left-sided devices. There were no relevant artifacts in patients with right-sided devices irrespective of the imaging sequence. In left-sided implants no PM-induced artifacts were found in first pass perfusion sequence, flow analysis and T1 weighted imaging. Only few patients with left-sided devices showed significant PM-artifacts in aortic (3/38, 7.9%)/mitral (n = 2/38, 5.3%) valve imaging and STIR (n = 3/35, 8.6%). In STIR only 14/805 (1.7%) segments were involved. In left-sided PM SSFP cine sequences had more artifact burden than LGE with 377/1505 (25.0%) vs. 162/1505 (10.8%) myocardial segments involved by relevant artifacts respectively (p < 0.001). Apart from cine and LGE imaging in anterior myocardial segments with left-sided implants presence of MRI conditional pacemakers does not affect CMR image quality in multimodal CMR examinations to a significant extent. Our data supports evidence that reduced image quality does not need to be a major concern in PM patients undergoing CMR.

Indexed as

ArtifactsCoronary CirculationMagnetic Resonance Imaging, CinePacemaker, ArtificialAdenosineAgedAged, 80 and overAortic ValveArrhythmias, CardiacContrast MediaEquipment DesignFemaleHumansImage Interpretation, Computer-AssistedMaleMiddle AgedAdenosineContrast MediaVasodilator AgentsCardiac magnetic resonanceCMRImage qualityMRI conditionalPacemaker