ArticleSurgical endoscopy2017
First series of total robotic hysterectomy (TRH) using new integrated table motion for the da Vinci Xi: feasibility, safety and efficacy.
Article in Surgical endoscopy, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Consensus-led recommendations defining practical principles of achieving optimal surgical outcomes in robotic colorectal surgery in the Asia-Pacific region.Journal of robotic surgery · 2023Article
- The role of robotic-assisted surgery for the treatment of diverticular disease.Journal of robotic surgery · 2020Article
- A prospective, single-arm study on the use of the da Vinci® Table Motion with the Trumpf TS7000dV operating table.Surgical endoscopy · 2018Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo present the first case series of total robotic hysterectomy (TRH), using integrated table motion (ITM), which is a new feature comprising a unique operating table by Trumpf Medical that communicates wirelessly with the da Vinci Xi surgical system. ITM has been specifically developed to improve multiquadrant robotic surgery such as that conducted in colorectal surgery.
methodsBetween May and October 2015, a prospective post-market study was conducted on ITM in the EU in 40 cases from different specialties. The gynecological study group comprised 12 patients. Primary endpoints were ITM feasibility, safety and efficacy.
resultsTen patients underwent TRH. Mean number of ITM moves was three during TRH; there were 31 instances of table moves in the ten procedures. Twenty-eight of 31 ITM moves were made to gain internal exposure. The endoscope remained inserted during 29 of the 31 table movements (94%), while the instruments remained inserted during 27 of the 31 moves (87%). No external instrument collisions or other problems related to the operating table were noted. There were no ITM safety-related observations and no adverse events.
conclusionsThis preliminary study demonstrated the feasibility, safety and efficacy of ITM for the da Vinci Xi surgical system in TRH. ITM was safe, with no adverse events related to its use. Further studies will be useful to define the real role and potential benefit of ITM in gynecological surgery.
Indexed as
Identifiers
27815747What OpenQuestion holds
Registered trials