Evidence map›Paper›PMID 27814429›Full record

ArticleJournal of biomechanical engineering2017

Effects of Residual Stress, Axial Stretch, and Circumferential Shrinkage on Coronary Plaque Stress and Strain Calculations: A Modeling Study Using IVUS-Based Near-Idealized Geometries.

Liang Wang, Jian Zhu, Habib Samady, David Monoly, Jie Zheng, Xiaoya Guo, Akiko Maehara, Chun Yang, Genshan Ma, Gary S Mintz and 1 more

Abstract read
In one paragraph

Article in Journal of biomechanical engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 7 institutions in 2 countries.

Liang WangMathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA 01609.
Jian ZhuDepartment of Cardiology, Zhongda Hospital, Southeast University, Nanjing 210009, China.
Habib SamadyDepartment of Medicine, Emory University School of Medicine, Atlanta, GA 30307.
David MonolyDepartment of Medicine, Emory University School of Medicine, Atlanta, GA 30307.
Jie ZhengMallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63110.
Xiaoya GuoDepartment of Mathematics, Southeast University, Nanjing 210096, China.
Akiko MaeharaThe Cardiovascular Research Foundation, Columbia University, New York, NY 10022.
Chun YangNetwork Technology Research Institute, China United Network Communications Co., Ltd., Beijing 100140, China.
Genshan MaDepartment of Cardiology, Zhongda Hospital, Southeast University, Nanjing 210009, China.
Gary S MintzThe Cardiovascular Research Foundation, Columbia University, New York, NY 10022.
Dalin TangMathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA 01609;Department of Mathematics, Southeast University, Nanjing 210096, China.
Columbia University · USEmory University · USWorcester Polytechnic Institute · USZhongda Hospital Southeast University · CNChina United Network Communications Group (China) · CNMallinckrodt (United States) · USSoutheast University · CN

Funding

In Vivo IVUS Image-Based Modeling for Human Coronary Plaque AssessmentR01EB004759 · NIBIB · WORCESTER POLYTECHNIC INSTITUTE · PI TANG, DALIN, ZHENG, JIE · 2004 to 2013
$2.4M
NIBIB NIH HHS R01 EB004759
6 · The paper itself

Abstract

Accurate stress and strain calculations are important for plaque progression and vulnerability assessment. Models based on in vivo data often need to form geometries with zero-stress/strain conditions. The goal of this paper is to use IVUS-based near-idealized geometries and introduce a three-step model construction process to include residual stress, axial shrinkage, and circumferential shrinkage and investigate their impacts on stress and strain calculations. In Vivo intravascular ultrasound (IVUS) data of human coronary were acquired for model construction. In Vivo IVUS movie data were acquired and used to determine patient-specific material parameter values. A three-step modeling procedure was used to make our model: (a) wrap the zero-stress vessel sector to obtain the residual stress; (b) stretch the vessel axially to its length in vivo; and (c) pressurize the vessel to recover its in vivo geometry. Eight models were constructed for our investigation. Wrapping led to reduced lumen and cap stress and increased out boundary stress. The model with axial stretch, circumferential shrink, but no wrapping overestimated lumen and cap stress by 182% and 448%, respectively. The model with wrapping, circumferential shrink, but no axial stretch predicted average lumen stress and cap stress as 0.76 kPa and -15 kPa. The same model with 10% axial stretch had 42.53 kPa lumen stress and 29.0 kPa cap stress, respectively. Skipping circumferential shrinkage leads to overexpansion of the vessel and incorrect stress/strain calculations. Vessel stiffness increase (100%) leads to 75% lumen stress increase and 102% cap stress increase.

Indexed as

Models, CardiovascularCompressive StrengthComputer SimulationCoronary Artery DiseaseElasticity Imaging TechniquesElastic ModulusHumansImage Interpretation, Computer-AssistedMaleMiddle AgedPlaque, AtheroscleroticShear StrengthStress, MechanicalTensile StrengthUltrasonography, InterventionalViscosity

Identifiers

PMID27814429
PMCPMC5125309
OpenAlexW2547394222

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.