Evidence map›Paper›PMID 27812311›Full record

ArticleBiochemia medica2016

Abnormal gel flotation caused by contrast media during adrenal vein sampling.

Gabriel Lima-Oliveira, Giuseppe Lippi, Gian Luca Salvagno, Matteo Gelati, Antonella Bassi, Alberto Contro, Francesca Pizzolo, Gian Cesare Guidi

Open access · diamondAbstract read
In one paragraph

Article in Biochemia medica, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Gabriel Lima-OliveiraLaboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Italy.
Giuseppe LippiLaboratory of Clinical Chemistry and Hematology, Academic Hospital of Parma, Parma, Italy.
Gian Luca SalvagnoLaboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Italy.
Matteo GelatiLaboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Italy.
Antonella BassiLaboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Italy.
Alberto ControVascular Interventional Radiology Unit, Institute of Radiology, University of Verona, Italy.
Francesca PizzoloDivision of Internal Medicine, Department of Medicine, University of Verona, Italy.
Gian Cesare GuidiLaboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Italy.
University of Verona · ITResearch Institute of Radiology · BYUniversity of Parma · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDuring adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. MATERIALS AND

methodsA patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to
confirm the catheter's position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes.

resultsAt the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm

conclusionThe abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated
contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays.

Indexed as

VeinsAdrenal GlandsContrast MediaElectrophoresisHumansHyperaldosteronismMaleMiddle AgedContrast Mediablood specimen collectioncontrast mediagelsphlebotomypreanalytical phase

Identifiers

PMID27812311
PMCPMC5082217
OpenAlexW2530957553

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.