Evidence map›Paper›PMID 27812139›Full record

ArticlePloS one2016

Measuring 3D Hand and Finger Kinematics-A Comparison between Inertial Sensing and an Opto-Electronic Marker System.

Josien C van den Noort, Henk G Kortier, Nathalie van Beek, DirkJan H E J Veeger, Peter H Veltink

Erratum issuedOpen access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
4.2field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 48 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. The role of laboratory investigations in the classification of tremors.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2023
    Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Josien C van den NoortBiomedical Signals and Systems Group, MIRA Research Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands.
Henk G KortierBiomedical Signals and Systems Group, MIRA Research Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands.
Nathalie van BeekDepartment of Human Movement Sciences, Faculty of Behaviour and Movement Sciences, Vrije Universiteit Amsterdam, MOVE Research Institute Amsterdam, Amsterdam, the Netherlands.
DirkJan H E J VeegerDepartment of Human Movement Sciences, Faculty of Behaviour and Movement Sciences, Vrije Universiteit Amsterdam, MOVE Research Institute Amsterdam, Amsterdam, the Netherlands.
Peter H VeltinkBiomedical Signals and Systems Group, MIRA Research Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands.
University of Twente · NLVrije Universiteit Amsterdam · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective analysis of hand and finger kinematics is important to increase understanding of hand function and to quantify motor symptoms for clinical diagnosis. The aim of this paper is to compare a new 3D measurement system containing multiple miniature inertial sensors (PowerGlove) with an opto-electronic marker system during specific finger tasks in three healthy subjects. Various finger movements tasks were performed: flexion, fast flexion, tapping, hand open/closing, ab/adduction and circular pointing. 3D joint angles of the index finger joints and position of the thumb and index were compared between systems. Median root mean square differences of the main joint angles of interest ranged between 3.3 and 8.4deg. Largest differences were found in fast and circular pointing tasks, mainly in range of motion. Smallest differences for all 3D joint angles were observed in the flexion tasks. For fast finger tapping, the thumb/index amplitude showed a median difference of 15.8mm. Differences could be explained by skin movement artifacts caused by relative marker movements of the marker system, particularly during fast tasks; large movement accelerations and angular velocities which exceeded the range of the inertial sensors; and by differences in segment calibrations between systems. The PowerGlove is a system that can be of value to measure 3D hand and finger kinematics and positions in an ambulatory setting. The reported differences need to be taken into account when applying the system in studies understanding the hand function and quantifying hand motor symptoms in clinical practice.

Indexed as

Electrical Equipment and SuppliesLightMechanical PhenomenaAdultBiomechanical PhenomenaFemaleFingersHandHumansMale

Identifiers

PMID27812139
PMCPMC5094774
OpenAlexW2548566420

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.