SynthesisBMJ open2016
Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review.
Synthesis in BMJ open, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 2 syntheses or guidelines pooled it, 51 citations in OpenAlex.
- Investigation and management of resistant hypertension: British and Irish Hypertension Society position statement.Journal of human hypertension · 2025Guideline
- Brazilian Guidelines for In-office and Out-of-office Blood Pressure Measurement - 2023.Arquivos brasileiros de cardiologia · 2024Guideline
- Blood pressure increases are associated with weight gain and not antiretroviral regimen or kidney function: a secondary analysis from the ADVANCE trial in South Africa.Journal of the International AIDS Society · 2024Trial
- 2024 Thai guidelines on the treatment of hypertension.Asian biomedicine : research, reviews and news · 2025Article
- Challenges in blood pressure measurement in children with obesity: focus on the cuff.Pediatric nephrology (Berlin, Germany) · 2025Review
- Advances in the Pathogenesis and Treatment of Resistant Hypertension.International journal of molecular sciences · 2023Review
- Addressing the diagnostic gap in hypertension through possible interventions and scale-up: A microsimulation study.PLoS medicine · 2022Article
- Pregnancy Care for Patients With Super Morbid Obesity.Frontiers in pediatrics · 2022Review
- Home blood pressure monitoring: methodology, clinical relevance and practical application: a 2021 position paper by the Working Group on Blood Pressure Monitoring and Cardiovascular Variability of the European Society of Hypertension.Journal of hypertension · 2021Article
- Brazilian Guidelines of Hypertension - 2020.Arquivos brasileiros de cardiologia · 2021Article
- The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial.Florence Nightingale journal of nursing · 2020Article
- Analyzing 24-Hour Blood Pressure Measurements with a Novel Cuffless Pulse Transit Time Device in Clinical Practice-Does the Software for Heartbeat Detection Matter?Diagnostics (Basel, Switzerland) · 2020Article
- Rationale and design of a nurse-led intervention to extend the HIV treatment cascade for cardiovascular disease prevention trial (EXTRA-CVD).American heart journal · 2019Article
- Accuracy of non-invasive and minimally invasive hemodynamic monitoring: where do we stand?Annals of translational medicine · 2019Review
- Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association.Hypertension (Dallas, Tex. : 1979) · 2019Review
- Obesity-Induced Hypertension: Heavy on the Accelerator.Journal of the American Heart Association · 2019Article
- Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research: JACC Scientific Expert Panel.Journal of the American College of Cardiology · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
objectiveTo determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference.
designSystematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. DATA SOURCES: MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. ELIGIBILITY CRITERIA: Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included.
results4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement.
conclusionsBP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.