Evidence map›Paper›PMID 27803904›Full record

ArticleEndoscopic ultrasound

Endoscopic ultrasonography-guided placement of a transhepatic portal vein stent in a live porcine model.

Tae Young Park, Dong Wan Seo, Hyeon-Ji Kang, Min Keun Cho, Tae Jun Song, Do Hyun Park, Sang Soo Lee, Sung Koo Lee, Myung-Hwan Kim

Open access · greenAbstract read
In one paragraph

Article in Endoscopic ultrasound. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Review
  3. Endoscopic ultrasound-guided vascular interventions: An expanding paradigm.World journal of gastrointestinal endoscopy · 2023
    Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Diagnostic and Therapeutic Applications of Endoscopic Ultrasound.Saudi journal of medicine & medical sciences
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Tae Young ParkDepartment of Internal Medicine, Hallym University Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Korea.
Dong Wan SeoDepartment of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Hyeon-Ji KangDepartment of Gastroenterology, Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea.
Min Keun ChoDepartment of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Tae Jun SongDepartment of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Do Hyun ParkDepartment of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Sang Soo LeeDepartment of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Sung Koo LeeDepartment of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Myung-Hwan KimDepartment of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
University of Ulsan · KRUlsan College · KRHallym University Chuncheon Sacred Heart Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesPercutaneous portal vein (PV) stent placement is used to manage PV occlusion or stenosis caused by malignancy. The use of endoscopic ultrasonography (EUS) has expanded to include vascular interventions. The aim of this study was to examine the technical feasibility and safety of EUS-guided transhepatic PV stent placement in a live porcine model. MATERIALS AND

methodsEUS-guided transhepatic PV stent placement was performed in six male miniature pigs under general anesthesia using forward-viewing echoendoscope. Under EUS guidance, the left intrahepatic PV was punctured with a 19-gauge fine-needle aspiration (FNA) needle and a 0.025 inch guidewire inserted through the needle and into the main PV. The FNA needle was then withdrawn and a needle-knife inserted to dilate the tract. Under EUS and fluoroscopic guidance, a noncovered metal stent was inserted over the guidewire and released into the main PV.

resultsA PV stent was placed successfully in all six pigs with no technical problems or complications. The patency of the stent in the main PV was confirmed using color Doppler EUS and transhepatic portal venography. Necropsy of the first three animals revealed no evidence of bleeding and damage to intra-abdominal organs or vessels. No complications occurred in the remaining three animals during the 8 weeks observation period.

conclusionsEUS-guided transhepatic PV stent placement can be both technically feasible and safe in a live animal model.

Indexed as

Endoscopic ultrasonographyfeasibilityportal veinsafetystent

Identifiers

PMID27803904
PMCPMC5070289
OpenAlexW2529017002

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.