Evidence map›Paper›PMID 27790540›Full record

ArticleJournal of clinical and diagnostic research : JCDR2016

A Randomized Trial Comparing Efficacy of Bubble and Ventilator Derived Nasal CPAP in Very Low Birth Weight Neonates with Respiratory Distress.

Sheetal Agarwal, Arti Maria, Mahesh K Roy, Ankit Verma

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical and diagnostic research : JCDR, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sheetal AgarwalAssistant Professor, Department of Pediatrics, PGIMER and Dr. RML Hospital , Delhi, India .
Arti MariaHead, Department of Neonatology, PGIMER and Dr. RML Hospital , Delhi, India .
Mahesh K RoySenior Resident, Department of Pediatrics, PGIMER and Dr. RML Hospital , Delhi, India .
Ankit VermaSenior Resident, Department of Pediatrics, PGIMER and Dr. RML Hospital , Delhi, India .
Post Graduate Institute of Medical Education and Research · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionContinuous Positive Airway Pressure (CPAP) has an established role in the care of Very Low Birth Weight (VLBW) babies with respiratory distress. Bubble CPAP (BCPAP) is a cheap alternative for countries where resources are limited. However, data comparing efficacy of BCPAP with conventional ventilator derived (VCPAP) is limited.

aimTo compare CPAP failure rates between BCPAP and VCPAP among VLBW, with moderate respiratory distress. Secondary objectives were to compare the rates of Intraventricular Haemorrhage (IVH), pulmonary air leaks and deaths between the two groups and determine the predictors of CPAP failure. MATERIALS AND

methodsVLBW babies with moderate respiratory distress (Silverman Anderson score 4-7), born or admitted in Neonatal Intensive Care Unit (NICU) within 28 days of life were randomized to receive either BCPAP (n=34) or VCPAP (n=34). CPAP failure rate in both the groups was compared.

resultsThe baseline characteristics were similar in both the groups. Five out of 34 (14.70%) babies in BCPAP group and 11 out of 34 (32.35%) in VCPAP failed CPAP (p=0.08). IVH (BCPAP group 24% and VCPAP group 9%, p= 0.10) and mortality (BCPAP group 6% and VCPAP group 9%, p=0.642) were comparable in both the groups. Factors such as gestational age <30 weeks, weight <1000 grams, Respiratory Distress Syndrome (RDS), shock, pulmonary haemorrhage, Disseminated Intravascular Coagulation (DIC) and multi-organ dysfunction were significantly associated with CPAP failure in our study.

conclusionThe CPAP failure rates in VLBW babies with moderate respiratory distress were found to be similar whether bubble CPAP or ventilator CPAP was used. There was no difference in complication rates of IVH or mortality with either method of CPAP.

Indexed as

Failure rateNewbornPressure delivery system

Identifiers

PMID27790540
PMCPMC5072040
OpenAlexW2529810772

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.