Evidence map›Paper›PMID 27790158›Full record

ArticleFrontiers in physiology2016

Regularization Techniques for ECG Imaging during Atrial Fibrillation: A Computational Study.

Carlos Figuera, Víctor Suárez-Gutiérrez, Ismael Hernández-Romero, Miguel Rodrigo, Alejandro Liberos, Felipe Atienza, María S Guillem, Óscar Barquero-Pérez, Andreu M Climent, Felipe Alonso-Atienza

Erratum issuedAbstract read
In one paragraph

Article in Frontiers in physiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 22 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Electrocardiographic imaging in the atria.Medical & biological engineering & computing · 2023
    Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Statistical guidance of VT ablation.Journal of cardiovascular electrophysiology · 2018
    Article
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Carlos FigueraDepartment of Telecommunication Engineering, Universidad Rey Juan Carlos Fuenlabrada, Spain.
Víctor Suárez-GutiérrezDepartment of Telecommunication Engineering, Universidad Rey Juan Carlos Fuenlabrada, Spain.
Ismael Hernández-RomeroDepartment of Telecommunication Engineering, Universidad Rey Juan Carlos Fuenlabrada, Spain.
Miguel RodrigoITACA, Universitat Politécnica de Valencia Valencia, Spain.
Alejandro LiberosInstituto de Investigación Sanitaria Gregorio Marañón, Hospital General Univesitario Gregorio Marañón, Universidad Complutense-Facultad de Medicina Madrid, Spain.
Felipe AtienzaInstituto de Investigación Sanitaria Gregorio Marañón, Hospital General Univesitario Gregorio Marañón, Universidad Complutense-Facultad de Medicina Madrid, Spain.
María S GuillemITACA, Universitat Politécnica de Valencia Valencia, Spain.
Óscar Barquero-PérezDepartment of Telecommunication Engineering, Universidad Rey Juan Carlos Fuenlabrada, Spain.
Andreu M ClimentITACA, Universitat Politécnica de ValenciaValencia, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Hospital General Univesitario Gregorio Marañón, Universidad Complutense-Facultad de MedicinaMadrid, Spain.
Felipe Alonso-AtienzaDepartment of Telecommunication Engineering, Universidad Rey Juan Carlos Fuenlabrada, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The inverse problem of electrocardiography is usually analyzed during stationary rhythms. However, the performance of the regularization methods under fibrillatory conditions has not been fully studied. In this work, we assessed different regularization techniques during atrial fibrillation (AF) for estimating four target parameters, namely, epicardial potentials, dominant frequency (DF), phase maps, and singularity point (SP) location. We use a realistic mathematical model of atria and torso anatomy with three different electrical activity patterns (i.e., sinus rhythm, simple AF, and complex AF). Body surface potentials (BSP) were simulated using Boundary Element Method and corrupted with white Gaussian noise of different powers. Noisy BSPs were used to obtain the epicardial potentials on the atrial surface, using 14 different regularization techniques. DF, phase maps, and SP location were computed from estimated epicardial potentials. Inverse solutions were evaluated using a set of performance metrics adapted to each clinical target. For the case of SP location, an assessment methodology based on the spatial mass function of the SP location, and four spatial error metrics was proposed. The role of the regularization parameter for Tikhonov-based methods, and the effect of noise level and imperfections in the knowledge of the transfer matrix were also addressed. Results showed that the Bayes maximum-a-posteriori method clearly outperforms the rest of the techniques but requires a priori information about the epicardial potentials. Among the purely non-invasive techniques, Tikhonov-based methods performed as well as more complex techniques in realistic fibrillatory conditions, with a slight gain between 0.02 and 0.2 in terms of the correlation coefficient. Also, the use of a constant regularization parameter may be advisable since the performance was similar to that obtained with a variable parameter (indeed there was no difference for the zero-order Tikhonov method in complex fibrillatory conditions). Regarding the different targets, DF and SP location estimation were more robust with respect to pattern complexity and noise, and most algorithms provided a reasonable estimation of these parameters, even when the epicardial potentials estimation was inaccurate. Finally, the proposed evaluation procedure and metrics represent a suitable framework for techniques benchmarking and provide useful insights for the clinical practice.

Indexed as

atrial fibrillationdominant frequencyECG imaginginverse problemregularizationrotor location

Identifiers

PMID27790158
PMCPMC5064166

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.