Practical issues regarding angular and energy response in in vivo intraoperative electron radiotherapy dosimetry.

Juan López-Tarjuelo, Ana Bouché-Babiloni, Virginia Morillo-Macías, Agustín Santos-Serra, Carlos Ferrer-Albiach

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Juan López-TarjueloServicio de Radiofísica y Protección Radiológica, Consorcio Hospitalario Provincial de Castellón, Avda. Dr. Clará, 19, Castellón de la Plana 12002, Spain.
Ana Bouché-BabiloniServicio de Oncología Radioterápica, Consorcio Hospitalario Provincial de Castellón, Avda. Dr. Clará, 19, Castellón de la Plana 12002, Spain.
Virginia Morillo-MacíasServicio de Oncología Radioterápica, Consorcio Hospitalario Provincial de Castellón, Avda. Dr. Clará, 19, Castellón de la Plana 12002, Spain.
Agustín Santos-SerraServicio de Radiofísica y Protección Radiológica, Consorcio Hospitalario Provincial de Castellón, Avda. Dr. Clará, 19, Castellón de la Plana 12002, Spain.
Carlos Ferrer-AlbiachServicio de Oncología Radioterápica, Consorcio Hospitalario Provincial de Castellón, Avda. Dr. Clará, 19, Castellón de la Plana 12002, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo estimate angular response deviation of MOSFETs in the realm of intraoperative electron radiotherapy (IOERT), review their energy dependence, and propose unambiguous names for detector rotations.

backgroundMOSFETs have been used in IOERT. Movement of the detector, namely rotations, can spoil results. MATERIALS AND

methodsWe propose yaw, pitch, and roll to name the three possible rotations in space, as these unequivocally name aircraft rotations. Reinforced mobile MOSFETs (model TN-502RDM-H) and an Elekta Precise linear accelerator were used. Two detectors were placed in air for the angular response study and the whole set of five detectors was calibrated as usual to evaluate energy dependence.

resultsThe maximum readout was obtained with a roll of 90° and 4 MeV. With regard to pitch movement, a substantial drop in readout was achieved at 90°. Significant overresponse was measured at 315° with 4 MeV and at 45° with 15 MeV. Energy response is not different for the following groups of energies: 4, 6, and 9 MeV; and 12 MeV, 15 MeV, and 18 MeV.

conclusionsOur proposal to name MOSFET rotations solves the problem of defining sensor orientations. Angular response could explain lower than expected results when the tip of the detector is lifted due to inadvertent movements. MOSFETs energy response is independent of several energies and differs by a maximum of 3.4% when dependent. This can limit dosimetry errors and makes it possible to calibrate the detectors only once for each group of energies, which saves time and optimizes lifespan of MOSFETs.

Indexed as

Angular responseANOVA, analysis of varianceCF, calibration factorEnergy dependenceGH, Games–Howell testIOERTIOERT, intraoperative electron radiotherapyMOSFETMOSFET, metal oxide semiconductor field effect transistorRotationsT, Tukey's test