Evidence map›Paper›PMID 27788689›Full record

ArticleBMC structural biology2016

Combined small angle X-ray solution scattering with atomic force microscopy for characterizing radiation damage on biological macromolecules.

Luca Costa, Alexander Andriatis, Martha Brennich, Jean-Marie Teulon, Shu-Wen W Chen, Jean-Luc Pellequer, Adam Round

Open access · hybridAbstract read
In one paragraph

Article in BMC structural biology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Solution structure and assembly of β-amylase 2 from Arabidopsis thaliana.Acta crystallographica. Section D, Structural biology · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 4 countries.

Luca CostaESRF, The European Synchrotron, 71 Avenue des Martyrs, Grenoble, 38000, France.
Alexander AndriatisESRF, The European Synchrotron, 71 Avenue des Martyrs, Grenoble, 38000, France.
Martha BrennichESRF, The European Synchrotron, 71 Avenue des Martyrs, Grenoble, 38000, France.
Jean-Marie TeulonUniv. Grenoble Alpes, 71 Avenue des Martyrs, Grenoble, 38044, France.
Shu-Wen W ChenUniv. Grenoble Alpes, 71 Avenue des Martyrs, Grenoble, 38044, France.
Jean-Luc PellequerUniv. Grenoble Alpes, 71 Avenue des Martyrs, Grenoble, 38044, France. jean-luc.pellequer@ibs.fr.ORCID 0000-0002-8944-2715
Adam RoundEuropean Molecular Biology Laboratory, 71 Avenue des Martyrs, Grenoble, 38000, France.
Centre National de la Recherche Scientifique · FREuropean Synchrotron Radiation Facility · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSynchrotron radiation facilities are pillars of modern structural biology. Small-Angle X-ray scattering performed at synchrotron sources is often used to characterize the shape of biological macromolecules. A major challenge with high-energy X-ray beam on such macromolecules is the perturbation of sample due to radiation damage.

resultsBy employing atomic force microscopy, another common technique to determine the shape of biological macromolecules when deposited on flat substrates, we present a protocol to evaluate and characterize consequences of radiation damage. It requires the acquisition of images of irradiated samples at the single molecule level in a timely manner while using minimal amounts of protein. The protocol has been tested on two different molecular systems: a large globular tetremeric enzyme (β-Amylase) and a rod-shape plant virus (tobacco mosaic virus). Radiation damage on the globular enzyme leads to an apparent increase in molecular sizes whereas the effect on the long virus is a breakage into smaller pieces resulting in a decrease of the average long-axis radius.

conclusionsThese results show that radiation damage can appear in different forms and strongly support the need to check the effect of radiation damage at synchrotron sources using the presented protocol.

Indexed as

Microscopy, Atomic ForceScattering, Small AngleAmylasesIpomoea batatasNickelProtein Structure, QuaternaryTobacco Mosaic VirusX-Ray DiffractionX-RaysAmylasesNickelnickel chlorideAtomic force microscopy (AFM)Radiation damageSmall angle x-ray scattering (SAXS)Tobacco mosaic virusβ-Amylase

Identifiers

PMID27788689
PMCPMC5081678
OpenAlexW2542628397

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.