Evidence map›Paper›PMID 27785136›Full record

ArticleKardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery2016

Monitoring hemostasis parameters in left ventricular assist device recipients - a preliminary report.

Bartosz Hudzik, Jacek Kaczmarski, Jerzy Pacholewicz, Michał Zakliczyński, Mariusz Gąsior, Marian Zembala

Abstract read
In one paragraph

Article in Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Device-Induced Hemostatic Disorders in Mechanically Assisted Circulation.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bartosz Hudzik3 Department of Cardiology, Silesian Centre for Heart Disease, SMDZ in Zabrze, Medical University of Silesia in Katowice, Poland.
Jacek KaczmarskiHemostasis Laboratory, Silesian Centre for Heart Disease, Zabrze, Poland.
Jerzy PacholewiczDepartment of Cardiac, Vascular and Endovascular Surgery and Transplantology, Silesian Centre for Heart Disease, SMDZ in Zabrze, Medical University of Silesia in Katowice, Poland.
Michał ZakliczyńskiDepartment of Cardiac, Vascular and Endovascular Surgery and Transplantology, Silesian Centre for Heart Disease, SMDZ in Zabrze, Medical University of Silesia in Katowice, Poland.
Mariusz Gąsior3 Department of Cardiology, Silesian Centre for Heart Disease, SMDZ in Zabrze, Medical University of Silesia in Katowice, Poland.
Marian ZembalaDepartment of Cardiac, Vascular and Endovascular Surgery and Transplantology, Silesian Centre for Heart Disease, SMDZ in Zabrze, Medical University of Silesia in Katowice, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMechanical circulatory support (MCS) therapy is associated with the improvement of long-term prognosis in patients with end-stage heart failure. For years it has been used as a bridge to transplant. However, more recently it is even being used as a destination therapy. Recently, clinicians have identified common MCS therapy-associated complications: pump thrombosis, bleeding, and hemolysis. These complications are very challenging with regard to both diagnosis and management.

aimTo determine time-dependant changes of selected hemostasis/coagulation parameters in patients with end-stage heart failure treated with MCS and antithrombotic therapy. MATERIAL AND

methodsSixteen patients with end-stage heart failure on left ventricular assist device (LVAD) were followed for 6 weeks (six blood samples for each patient). Every week an extended hemostasis panel was assessed, including activated partial thromboplastin time, prothrombin time, international normalized ratio, von Willebrand factor (vWF) activity, factor VIII activity, fibrinogen level, D-dimer, platelet response to arachidonic acid (ASPI test) and adenosine diphosphate (ADP test), thrombin receptor activating peptide-6 (TRAP test) and collagen (COL test).

resultsThe study population comprised 16 men. The median time from LVAD implantation was 120 days (100-150 days). During the study period the D-dimer and fibrinogen concentrations were elevated but remained similar throughout all six measurements. Meanwhile factor VIII and vWF activities were elevated in the first two measurements and then subsequently declined. Inhibition of platelet aggregation was greater early after LVAD implantation. During subsequent weeks the inhibition of platelet aggregation was less pronounced. No patient developed any bleeding or thrombo-embolic event during the study period.

conclusionsPatients on MCS therapy demonstrate significant time-dependant changes in hemostasis parameters (both in the coagulation system and platelet aggregation).

Indexed as

bleedingleft ventricular assist devicemechanical circulatory supportthrombosis

Identifiers

PMID27785136
PMCPMC5071589

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.