Evidence map›Paper›PMID 27781040›Full record

ArticleInterventional neurology2016

Safety Outcomes Using a Proximal Protection Device in Carotid Stenting of Long Carotid Stenoses.

Kunakorn Atchaneeyasakul, Priyank Khandelwal, Sudheer Ambekar, Kevin Ramdas, Luis Guada, Dileep Yavagal

Open access · bronzeAbstract read
In one paragraph

Article in Interventional neurology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kunakorn AtchaneeyasakulInterventional Division, Department of Neurology, University of Miami Miller School of Medicine, Miami, Fla., USA.
Priyank KhandelwalInterventional Division, Department of Neurology, University of Miami Miller School of Medicine, Miami, Fla., USA.
Sudheer AmbekarInterventional Division, Department of Neurology, University of Miami Miller School of Medicine, Miami, Fla., USA.
Kevin RamdasInterventional Division, Department of Neurology, University of Miami Miller School of Medicine, Miami, Fla., USA.
Luis GuadaInterventional Division, Department of Neurology, University of Miami Miller School of Medicine, Miami, Fla., USA.
Dileep YavagalInterventional Division, Department of Neurology, University of Miami Miller School of Medicine, Miami, Fla., USA.
University of Miami · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEmbolic protection devices can prevent atherosclerotic emboli during carotid stenting. Newer proximal protection devices reverse flow in the internal carotid artery (ICA), leading to reduction in perioperative microemboli. The risk of stroke is high for carotid stenting of ICA lesions with a length >10 mm and/or angiographic string sign.

objectiveWe aimed to evaluate the safety outcomes of proximal embolic protection device usage in this high-risk group.

methodsThis is a retrospective analysis of patients who underwent carotid stenting procedures with proximal embolic protection devices at a tertiary care center. High-risk features for adverse events with carotid stenting were identified. Peri- and postprocedural outcomes were recorded. We further compared outcomes in patients with a carotid stenosis length >10 mm to those with shorter stenosis.

resultsFrom January 2011 to December 2014, we included 27 patients; 96.3% were symptomatic and 3.7% were asymptomatic. There was a stent placement technical success rate of 100%. No major stroke or coronary events were recorded. One minor stroke event developed in one patient. A carotid lesion length >10 mm and/or angiographic string sign was noted in 21/27 patients, with an average lesion length of 14.4 mm. One patient (4.8%) in this group developed a minor stroke event. Neither a coronary nor a major stroke event was recorded in this group. There was no significant difference in the complication rate between the long lesion and the control group.

conclusionIn our patient cohort, it was found that a proximal embolic protection device is safe for patients with carotid stenosis, including those with a carotid lesion length >10 mm and/or angiographic string sign.

Indexed as

Carotid stenosisCarotid stentMicroemboliProximal protectionStroke

Identifiers

PMID27781040
PMCPMC5075902
OpenAlexW2438701944

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked