Evidence map›Paper›PMID 27777761›Full record

ArticleAntimicrobial resistance and infection control2016

A pilot study to assess use of fluorescent lotion in patient care simulations to illustrate pathogen dissemination and train personnel in correct use of personal protective equipment.

Heba Alhmidi, Sreelatha Koganti, Myreen E Tomas, Jennifer L Cadnum, Annette Jencson, Curtis J Donskey

Open access · goldAbstract read
In one paragraph

Article in Antimicrobial resistance and infection control, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Development and Comparison of Complementary Methods to Study Potential Skin and Inhalational Exposure to Pathogens During Personal Protective Equipment Doffing.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2019
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Heba AlhmidiResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH USA.
Sreelatha KogantiResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH USA.
Myreen E TomasGeriatric Research, Education, and Clinical Center, Cleveland Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, OH 44106 USA.
Jennifer L CadnumGeriatric Research, Education, and Clinical Center, Cleveland Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, OH 44106 USA.
Annette JencsonResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH USA.
Curtis J DonskeyGeriatric Research, Education, and Clinical Center, Cleveland Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, OH 44106 USA ; Case Western Reserve University School of Medicine, Cleveland, OH USA.
Geriatric Research Education and Clinical Center · USLouis Stokes Cleveland VA Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSimulations using fluorescent tracers can be useful in understanding the spread of pathogens and in devising effective infection control strategies.

methodsDuring simulated patient care interactions in which providers wore gloves and gowns, we evaluated environmental and personnel dissemination of fluorescent lotion and bacteriophage MS2 from a contaminated mannequin. The frequency of skin and clothing contamination after removal of personal protective equipment (PPE) was compared before versus after an intervention that included education and practice in PPE donning and doffing.

resultsTen healthcare personnel participated in 30 pre-intervention and 30 post-intervention patient care simulations. Fluorescent lotion and bacteriophage MS2 were rapidly disseminated to touched surfaces throughout the room; there was no difference in the frequency of contamination before versus after the PPE training intervention. After the intervention, there was a decrease in skin and/or clothing contamination with fluorescent lotion (9/30, 30 % versus 1/30, 3 %;

conclusionsOur findings suggest that simulations with fluorescent lotion can be a useful teaching tool to illustrate the spread of pathogens and provide further evidence that simple PPE training interventions can be effective in reducing contamination of personnel.

Indexed as

Bacteriophage MS2Fluorescent markerHealthcare personnelPersonal protective equipmentTraining

Identifiers

PMID27777761
PMCPMC5072336
OpenAlexW2532531122

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.