Evidence map›Paper›PMID 27776179›Full record

ArticlePloS one2016

3D Real-Time Echocardiography Combined with Mini Pressure Wire Generate Reliable Pressure-Volume Loops in Small Hearts.

Ulrike Herberg, Katharina Linden, Oliver Dewald, Eva Gatzweiler, Matthias Seehase, Georg Daniel Duerr, Jonas Dörner, Stephanie Kleppe, Dennis Ladage, Johannes Breuer

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 17 citations in OpenAlex.

  1. Left ventricular hemodynamics with veno-arterial extracorporeal membrane oxygenation.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2024
    Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Ulrike HerbergDepartment of Pediatric Cardiology, Pediatric Heart Center, University of Bonn, Bonn, Germany.ORCID http://orcid.org/0000-0002-9386-0258
Katharina LindenDepartment of Pediatric Cardiology, Pediatric Heart Center, University of Bonn, Bonn, Germany.
Oliver DewaldDepartment of Cardiac Surgery, Pediatric Heart Center, University of Bonn, Bonn, Germany.
Eva GatzweilerDepartment of Pediatric Cardiology, Pediatric Heart Center, University of Bonn, Bonn, Germany.
Matthias SeehaseDepartment of Pediatric Cardiology, Pediatric Heart Center, University of Bonn, Bonn, Germany.
Georg Daniel DuerrDepartment of Cardiac Surgery, Pediatric Heart Center, University of Bonn, Bonn, Germany.
Jonas DörnerDepartment of Radiology, University of Bonn, Bonn, Germany.
Stephanie KleppeDepartment of Pediatric Cardiology, Pediatric Heart Center, University of Bonn, Bonn, Germany.
Dennis LadageHeart Center of the University Hospital Cologne, Dept. III for Internal Medicine, Cologne, Germany.
Johannes BreuerDepartment of Pediatric Cardiology, Pediatric Heart Center, University of Bonn, Bonn, Germany.
University of Bonn · DEUniversity Hospital Cologne · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPressure-volume loops (PVL) provide vital information regarding ventricular performance and pathophysiology in cardiac disease. Unfortunately, acquisition of PVL by conductance technology is not feasible in neonates and small children due to the available human catheter size and resulting invasiveness. The aim of the study was to validate the accuracy of PVL in small hearts using volume data obtained by real-time three-dimensional echocardiography (3DE) and simultaneously acquired pressure data.

methodsIn 17 piglets (weight range: 3.6-8.0 kg) left ventricular PVL were generated by 3DE and simultaneous recordings of ventricular pressure using a mini pressure wire (PVL3D). PVL3D were compared to conductance catheter measurements (PVLCond) under various hemodynamic conditions (baseline, alpha-adrenergic stimulation with phenylephrine, beta-adrenoreceptor-blockage using esmolol). In order to validate the accuracy of 3D volumetric data, cardiac magnetic resonance imaging (CMR) was performed in another 8 piglets.

resultsCorrelation between CMR- and 3DE-derived volumes was good (enddiastolic volume: mean bias -0.03ml ±1.34ml). Computation of PVL3D in small hearts was feasible and comparable to results obtained by conductance technology. Bland-Altman analysis showed a low bias between PVL3D and PVLCond. Systolic and diastolic parameters were closely associated (Intraclass-Correlation Coefficient for: systolic myocardial elastance 0.95, arterial elastance 0.93, diastolic relaxation constant tau 0.90, indexed end-diastolic volume 0.98). Hemodynamic changes under different conditions were well detected by both methods (ICC 0.82 to 0.98). Inter- and intra-observer coefficients of variation were below 5% for all parameters.

conclusionsPVL3D generated from 3DE combined with mini pressure wire represent a novel, feasible and reliable method to assess different hemodynamic conditions of cardiac function in hearts comparable to neonate and infant size. This methodology may be integrated into clinical practice and cardiac catheterization programs and has the capability to contribute to clinical decision making even in small hearts.

Indexed as

Heart VentriclesAnimalsEchocardiographyMagnetic Resonance ImagingPressureSwine

Identifiers

PMID27776179
PMCPMC5077139
OpenAlexW2538191841

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.